Parenteral products contained in vial package systems require a robust seal at the interface between the glass vial and the elastomeric closure to prevent contamination and product leakage. The seal is established in the manufacturing process, but must withstand a variety of handling, processing and storage conditions.
Sutures are widely used in the biomedical industry. They are used in a variety of surgical procedures to allow for wound closure and aid in tissue healing. Sutures are manufactured from various different absorbable and nonabsorbable materials, and may be single filament or braided with or without a coating. There are some challenges in testing sutures. Loading the specimen alone can pose problems as some sutures are delicate and require a low amount of force to fracture. Also, some sutures are used inside wounds and are constantly in a hydrated environment.
Surgical tubing is used in a wide variety of applications, such as drains, feeding tubes, irrigation and surgical procedures, and therefore comes in many shapes and sizes. The mechanical performance of the material used is critical, as failure could seriously endanger a patient. Tensile tests are frequently performed in product development and quality control to evaluate properties of material strength and strain at break.
Sutures are used in a variety of different surgical procedures to close wounds and aid in tissue healing. They are manufactured from a variety of different absorbable and nonabsorbable materials, and may be a single filament or braided with or without a coating. Tensile strength is a critical measure of performance during and after surgical procedures. The strength of different knotting techniques must also be evaluated. The test method must determine breaking strength and corresponding elongation and adhere to Food and Drug Administration (FDA) guidelines. Precise, consistent and reliable measures of strength and strain are essential for product development and quality control.
With continued growth in the biomaterials market, characterization of the mechanical properties of soft tissues has become a rising interest. These properties allow for the understanding of tissue function and injury mechanisms, aiding engineers and researchers in the development of bio-engineered tissues, computer assisted and remote robotic surgical methods, and injury prevention recommendations. One of the challenges in testing soft tissues arises in gripping of the specimens. Biological tissues are often times wet, slippery or delicate. Any combination of these characteristics leaves the existing test methods far below the ideal gripping solution. The ultimate goal lies in the fixation of soft biological tissues without causing premature failure or slippage.
Use of a hypodermic needle is the most direct method for administering medication. The medication is usually injected intramuscularly, where there is a rich supply of blood vessels, or intravenously, allowing the medication to be absorbed into the blood stream and begin acting almost immediately. Hypodermic needles are usually manufactured out of stainless steel and the material and design must be tested to evaluate the needle’s maximum tensile strength and yield strength. The challenge in testing these tubular devices is in gripping the specimen without causing premature failure in the grip faces.
The Instron® low-force Planar Biaxial (or cruciform) System was designed to perform mechanical testing and property analyze soft tissues and biomaterials in two axes. This test system is highly configurable, designed to give maximum flexibility to soft tissue tests.
Nitinol is a shape memory, superelastic alloy for which the biomedical industry has found extensive uses. A few examples of the numerous applications that use Nitinol include stents, dental wires, catheter guide wires, internal fracture fixation devices, biopsy forceps and others.
Instron® provides two different needle testing systems ideally suited for needles used in abdominal, fistula, vascular, intestinal, and other surgical procedures. The curved needle puncture tester is used to evaluate needle sharpness and insertion force. The needle bend tester is used to ensure that the needles are strong enough to not bend excessively during use. With their tabletop design, both systems have a small footprint and take up minimal lab space. The testing systems operate with the Instron Bluehill® Software that provides test control, data acquisition, test results, and reports.
Characterization of the mechanical properties of soft tissue used in medical applications is at the forefront of biomedical engineering, tissue engineering and materials testing in both industry and academia. The mechanical characteristics of living tissue are required in order to accurately create bioengineered replacement tissues and for medical diagnostic purposes.
A key concern for dental restorative materials and adhesives is their tensile and shear bond strength to the tooth enamel. However, alignment errors associated with angularity and concentricity of the specimen can make pure tensile and shear testing difficult. In the tensile bond strength test, load is applied perpendicular to the bond line inducing pure tensile loads. However, this can be quite difficult as alignment errors can induce bending stresses which results in premature failure and consequently yielding incorrect low results The ISO 11405 standard seeks to address this problem with fixtures that ensure specimen alignment during test set up. The Instron BioPuls™ shear and tensile strength test fixtures meet and exceed the ISO requirements by addressing alignment of the specimen during preparation, as well as preventing loss of alignment during testing. The specimen preparation accessory follows the ISO recommendations for set up of the specimen prior to test. It comes with a complete set of tools including cups and studs for multiple test specimens.
A pharmaceutical manufacturer wanted to investigate the forces necessary to eject medications from various types of syringes and needles.
The BioPuls submersible pneumatic side action grips and temperature-controlled bath with pneumatic lifting and lowering mechanism is the ideal testing solution for a wide variety of biomedical testing applications.
Hydrogels are widely used in the biomedical industry for applications such as coatings for catheters, contact lenses, scaffolds, and wound dressings because these materials have the ability to absorb fluids and swell up to 2000 times their original size. Hydrogels are often implanted into the body to provide medical benefits and therefore must be tested in a simulated environment.
Medical adhesives are widely used in the biomedical industry for applications such as bandages, secondary dressings, and wound closure. The adhesive strength of these products must be clearly defined before put to use in a clinical setting. If the adhesive is not strong enough, the product may lead to infection or poor healing. If the adhesive is too strong, the underlying tissue may become damaged upon removal.
Nitinol is a shape memory, superelastic alloy for which the biomedical industry has found extensive uses. A few examples of the numerous applications that use Nitinol include stents, dental wires, catheter guide wires, internal fracture fixation devices, biopsy forceps and others. The major challenge in testing this material is accurate strain measurements. The Instron® Advanced Video Extensometer (AVE) is a solution which allows for strain measurement of Nitinol wire in cyclic loading and to failure.
Extensometers are often used to accurately measure the deformation of a material under mechanical loading. Due to the fragile nature of biological soft tissues, such as fascia, skin, and intestinal lining, a non-contacting extensometer is the ideal solution for measuring tensile strain in these specimens. The AVE uses a high-resolution digital camera and advanced real-time image processing to make precise axial and transverse (optional) strain measurements on test specimens. Because these tissue specimens are soft, moist, and vary in color, the challenge in acquiring strain data lies in the marking technique. The purpose of this study was to investigate different AVE marking techniques for biological tissues.
The Instron® Testmaster Automation System, configured to perform unattended tensile testing of biomedical cord and yarn specimens, provides an ideal solution for high-volume tests of medical sutures. Designed to accommodate specimens of varying lengths and thicknesses, the system utilizes barcode labels to pass specimen information and testing specifications to the Testmaster2 Automation Control Software. A typical automated test sequence includes the following steps: The robot retrieves a batch separator with a barcode label affixed from a rack, scans the barcode, and downloads the specimen and testing information to the Testmaster2 Automation Control Software. The separator is then discarded into a bin and a specimen is retrieved from the racks and placed into the tensile frame and tested. After the test, the specimen is removed via a specimen removal device at the back of the frame, which utilizes a low-noise, industrial vacuum to aid in full removal of the tested sutures from the grips area. The robot then inserts the next specimen to be tested.
The customer has delivered three different samples of medical packaging that were prepared into 1 inch wide specimens for testing. The seal strength of the packaging was to be evaluated in a 180 degree peel test as described by ASTM F 88 - Standard Test Method for Seal Strength of Flexible Barrier Materials.
Millions of people use contact lenses on a daily basis, making them one of the most widely used medical devices in the world. Preferred over eyeglasses, they are used for a variety of eye correction prescription and are manufactured in an array of forms ranging from hard to soft lenses. When testing lenses, loading the specimen into the grips can pose many problems: the soft lens material is slippery and delicate fracturs at very low forces; and the test specimens are extremely small, providing a limited amount of gripping surface. Contact lenses must also be tested in an environment that best simulates physiological conditions; ambient testing results in the drying out and cracking of the material.
Use caution when comparing the values of a 180 degree peel adhesion test without understanding the test instrument’s bandwidth and data acquisition settings.
Minimizing system downtime with preventative maintenance, rapid repair, software updates and expert technical support at a low predictable price.
Minimizing system downtime with preventative maintenance, rapid repair, software updates and expert technical support at a low predictable price.
Undergraduate and post-graduate students at the Institute of Polymeric Materials and Testing (ipmt) at Johannes Kepler University (JKU) in Linz in Austria can rely on three Instron electrodynamic testing systems to help them analyse the failure behaviour of polymers.
Questions you may want to ask before selecting a verification/calibration services provider.
Featuring a dual test space and long test stroke HDX Models are designed for high-capacity tension, compression, bend/flex, and shear testing.
For the first time ever, five members of Illinois Tool Works' (ITW) Test and Measurement Group will be combining forces at Control 2012, jointly presenting their offering under one roof. At the Stand 1522 in Hall 1, professional visitors will find a host of valuable information for testing a wide spectrum of materials and components, from hard to soft and from ductile to brittle.
Instron EXTEND Upgrade Packages allow users of Instron electromechanical test machines to provide their systems with enhanced functionality and latest safety features at the fraction of the cost of a new machine. The comprehensive, modular feature set designed specifically for the respective load frame includes new controllers and powerful signal conditioning modules, identical to those used on new Instron machines.
Within the medical device industry, regulatory agencies often test internally-based devices and implants in a physiological state. The Instron® BioBox meets the growing trend of testing actual medical devices and biomaterials at body temperature (37 °С). For large or long devices, testing in а liquid may not bе practical. As an alternative, testing inside а controlled air environment at body temperature provides а powerful solution. The BioBox can bе incorporated as а standard item on а new single column frame or in selected models already in operation. This bох permits the full travel test of sutures, catheter tubings, latex gloves, and а wide variety of other devices and biomaterials at physiologically relevant temperatures.
This issue of TechNotes includes an article on Bamboo Bikes – A “Growth” Industry. It also contains a Technical Tip on Strain Measurement When Testing Composites and a question with answer "Q: What is the most effective gripping technique for a composite specimen with a hard, smooth surface?".
Accreditation US Dept. of Commerce & NIST nvlap certificate of Accreditation
Instron Calibration Laboratory
Instron® Automated Testing Systems for the testing of Plastics are confi gured to perform unattended tensile and fl exural testing of rigid, plastic specimens of varying lengths and thicknesses (from 0.1 to 12 mm).
The 5900 Series Multi Station systems offer enhanced throughput with their ability to perform simultaneous, independent tests on up to five (5) separate specimens using a single load frame.
Industrial Series RD Models are designed for high-capacity compression testing of concrete cylinders, cubes and blocks. Constructed with operator safety of critical importance, these ultra-stiff frames are ideally suited for advanced testing of concrete mixes.
Featuring a dual test space and single footprint, DX Models are designed for high-capacity tension, compression, bend/flex, and shear testing.
Many tests performed in the medical device and biomaterials applications occur in vitro, in solution, or in similar fluid environments. To protect the internal electronics of testing systems, any liquid spilling or leaking from the bath should be prevented from finding its way inside the frame. The lnstron® BioCoat is а protective element for your lnstron 594х Testing Systems. The BioCoat creates а liquid resistant cover that not only protects the system, but also provides а smooth surface that is easy to clean. This additional layer of safety means that your investment in а top-quality tesitng system is protected and will ensure many years of reliable and repeatable test results.
SFX Series Testers have made quality, advanced technology, and superior support affordable for the spring industry. The SFX1560 Series features a tabletop frame and is available in capacities up to 30 kN (6,750 lbf).
Pneumatic action grips allows rapid, easy loading of specimens from delicate films to polymers and woven fabrics. This provides a very simple and efficient method for holding flat test specimens in applications where you can easily insert the specimen and quickly apply a clamping force. Both jaw faces automatically adjust to different specimen thickness to ensure that the line of tensile force remains concentric with the grip body. They can be equipped with a selection of interchangeable grip jaw faces in various sizes and choice of surfaces including smooth ground, rubber-coated and serrated. Line contact and special coated faces are also available. Grip control may incorporate a footswitch allowing hands-free operation for speed, simplicity-of-use and accuracy of alignment within the grips. In addition, grip opening and closing can be controlled from the testing machine, providing features such as automatic pretension and grip release on specimen break. Catalog number 2712-019 Rated capacity: 250 N (25 kgf, 50 lbf)
Instron® Automated Tensile Testing Systems for metals are configured to perform unattended tensile testing of metallic specimens of varying lengths and thicknesses. Tests to ASTM E8 and EN 10002-1 standards. Includes r and n value results as well as capability of r-bar/Delta r and Bake Hardening index. Standard system capacities of 100 and 200 kN (more available upon request).
This document constitutes the highest level of documentation of quality measures in the corporation. It takes precedence over any supporting documents.
Don’t miss out on this year’s offers
The new CEAST DAS 64K is a state-of-the-art Data Acquisition System designed for impact testing instruments. Compatible with the full range of CEAST impact testing systems, including pendulum type machines (CEAST 9000 Series) and drop towers (CEAST 9300 Series), it’s the key for instrumented impact testing. The DAS 64K also enables the data collection from instrumented tups or hammers on older models and non-CEAST impact machines.
This two-page flyer summarizes the main features of Bluehill Lite software. Bluehill Lite is a general purpose software package that is ideal for fundamental applications and standardized tensile, compression, flexure, peel, tear, friction and simple cyclic test requirements. Bluehill Lite is compatible with all Instron 3300 Series universal test systems.
This issue of TechNotes includes an article on Hobas Pipe USA Installs Giant Custom-Built Instron Frame. It also contains a Technical Tip Selecting a Pressure Transducer for Your Capillary Rheometer and a question with answer this issue is "Q: What is the resolution and accuracy of your Smart Rheo load call?".
Guide to the various components of a high-temperature tensile testing system--furnaces, grips, pull rods, and extensometry. Includes an important system configuration tool.
Learn how the demand for lightweight composite materials and structures for aerospace and automotive, along with the development of environmentally sustainable energy systems, have affected the requirements for physical and mechanical testing.
Instron offers the SI-Series of pendulum impact testers designed for testing metals in accordance with ASTM E23. Five models provide energy ranges from 25 - 300 ft-lbs (33.8 - 406.7 joule).
The Bluehill 3 Composites Application Module includes a collection of pre-configured test methods and supporting documentation that cover a variety of internationally recognized industry standards; such as ISO 14125, ISO 14126, ISO 527-4, ISO 527-5, ASTM D3039, ASTM C365, and more.
Instron® Professional Services have provided onsite validation and documentation services to support Installation Qualification/OperationalQualification (IQ/OQ) validation for many years. This service, provided by the original equipment manufacturer, is designed to ensure that your Instron testing equipment is suitable for its intended purpose and is capable of producing valid results (per FDA 21 CFR 820.72). Additionally, you save time and resources by using Instron Professional Services to complete the IQ/OQ validation testing. Our experienced service team will use Instrons proven documentation pack that is tailored to your individual needs and contains necessary IQ/OQ documents, calculation work sheets,and manuals.
Simulates fatigue loading of hip ste during a gait cycle.
www.instron.com Products for Materials Testing Designed to suit ElectroPuls™ test instruments, the 2742-102 and -202 mechanical wedge action grips are suitable for tension, compression and reverse-stress testing on a wide range of specimens and materials. The grips are mechanically operated and the open-fronted design provides easy specimen insertion, positioning and clamping.
The Biopuls submersible pneumatic versa grips provide an easy and efficient method for gripping test specimens, ranging from thin film polymers to biological tissues, in a fluid bath for tension and torsion mechanical testing.
Compliant with ASTM E 1012 standards, the New AlignPRO™ system is designed to assist you in the measurement, adjustment and verification of load string alignment.
Implants and the materials used for their production undergo extensive tests, which include the evaluation of the static and dynamic mechanical properties of the raw materials, components and systems. Many of these tests are internationally standardized, other testing proceduresare specific to a given application.
This issue of TechNotes includes an article on Predicting the Properties of Virtual Materials. It also contains a Technical Tip Grip It Right and a question with answer this issue is "Q: What is a “Virtual measurement”?".
Proper preparation of the specimen is a critical process for accurate material characterization. An appropriate preparation of the specimen, as well as an adequate notching procedure affect the final test results, generating reliable outcomes in the finish product performances. This is accomplished by several specimen preparation techniques, making them particularly suitable to select the most appropriate material and failure results analysis. According to the requirements of the main international standards, Instron® offers an extensive range of notching, milling, and punching machines designed to prepare specimens from thin to thick samples, as well as from soft to hard and reinforced plastic materials.
Polymer melts exhibit a complex f ow behavior and show a different fluidity based on the applied pressure. A deeper plastics material characterization can be achieved if more than one condition is used within a single experiment, following a multiple weight test procedure dedicated to advanced quality control and research purposes.
Thermoplastic materials are processed as fluids under the effect of temperature and pressure. The ability of melted materials to flow under pressure at set temperatures has a fundamental importance in polymer science and technology. The Instron line of CEAST Melt Flow Testers have been specifically designed for the easy and accurate measuring of the flow properties of plastics according to the related ISO and ASTM international standards.
Adapter to connect a single 350 ohm strain gauge to a strain channel on an Instron test machine. It is provided with spring loaded terminals for attachment of strain gauge leads and it is suitable for maximum strains of 5%.
In case you've missed some of our issues throughout the year, we've compiled this Special Edition Issue - Year at a Glance. You will find the most popular articles, technical tips, and Q&A of 2011. Here's to a fantastic year and the hopes of a great 2012!
This issue of TechNotes includes an article on Liquidmetal – Not Just for Terminators. It also contains a Technical Tip answering the question "When did you last change your oil?" The question with answer this issue is "Q: Our testing lab is moving to a new building. Do our testing systems require recalibration after the move?".
The Plastics Testing Solutions brochure is a 40-page, applications-focused, and standards-based brochure. Important standards such as ISO 527-1, -2, -3, ISO 11443, ISO 75, ASTM D638, Astm D3835, are covered in a detailed testing challenge and solution format. The brochure addresses the most prominent and widely-used standards in the materials testing industry for plastics. Test types such as Impact, Rheology, Thermo-Mechanical, Specimen Preparation, Mechanical Testing, Dynamic/fatigue, and Hardness are described in great detail.
新材料および新型再生医療製品の研究は、世界中で最先端の研究とされています。骨、軟組織(たとえば、腱、靱帯、皮膚、筋肉あるいは動脈)、交換生体材料、および人工組織と人工骨格に関しては、特性を測定し、またこれらのキャラクタライゼーションを行うため機械的な試験が行われます。試験は、単純な引張、圧縮あるいは曲げ試験から、疲労試験装置を用いる動的キャラクタライゼーション、さらには複雑な平面2 軸試 験までの範囲に及びます。
医療消耗品および医療機器には、病院あるいは手術環境において用いられる注射器、 注射針、縫合糸、ステープル、パッケージング、チュービング、カテーテル、医療用手袋、ガウン、マスク、外傷被覆用の接着剤とシーラント、およびその他多数の器具と道具が含まれます。器具に応じて引張、圧縮あるいは曲げ試験、動的あるいは疲労試験、あるいは衝撃試験またはねじりを応用した試験などの機械的試験を実施することができます。
歯科接着剤、アマルガム、陶材、ポリマーおよびセラミックスについては、生体外で試 験を行い、修復歯科術および置換歯科術で使用するための性能を測定します。 歯科インプラントについては、口腔内でのインプラントにおける長期性能を測定する ため疲労試験を行います。ここでは、歯科材料および歯科インプラントの試験に関する インストロンのソリューション例をいくつか紹介します。
インプラントデバイスには、心臓血管ステント留置術、血管内ステント留置術、および神経血管ステント留置術、ならびにこれらの留置術に関連する心臓弁およびペースメーカまでの送達システムから、聴覚インプラントあるいは眼内レンズ/ コンタクトレンズのような眼のインプラントにいたるまで、多くの種類があります。機械的試験には、構成金属あるいは構成合金の静的引張/ 圧縮試験、および器具全体の圧縮/ 曲げ試験から、ステント材料の疲労および圧力脈動の動的シミュレーションまで、多くの種類があります。
インストロンは、原材料の基礎的な静的試験から接合コンポーネントの衝撃負荷まで、さらには生体内における疲労および磨耗特性を評価する完全なシミュレーションまで、整形外科分野における機械的試験の豊富な経験を有しています。
Screw side-action grips provide a very simple and efficient method for holding test specimens in a wide range of applications. The dual - acting design of 2710-100 series grips means that jaw faces can be adjusted to accommodate different specimen thicknesses. This ensures that the line of tensile force remains concentric with the grip body. They can be equipped with a selection of terchangeable grip jaw faces in various sizes and choice of surfaces including smooth ground, rubber-coated and serrated. Line contact and special coated faces are also available. Jaw faces can be changed single-handedly in seconds without the use of tools or pins.
Catalog Number 2715-001 Rated capacity 2.5 kN (250 kgf, 500 lbf)
Industrial Series KPX Models are designed for high-capacity tension, compression, bend/flex, and shear testing. Featuring an ultra-large single test space and adjustable crosshead options, these frames deliver exceptional flexibility for a wide range of testing applications and are available in capacities ranging from 600 kN (135,000 lbf) to 3,500 kN (800,000 lbf).
Industrial Series KX Models are designed for high-capacity tension, compression, bend/flex, and shear testing. Featuring an ultra-large single test space and fixed height crosshead, these frames are available in capacities ranging from 600 kN (135,000 lbf) to 1,500 kN (337,500 lbf).
5900 EXTENDによるアップグレードを利用されると、ご利用中の荷重フレーム、グリップ、およびロードセルをそのまま使用しながら、旧式のエレクトロニクスと記録装置を、新しいプロダクティビティパネルと新しい先進的試験ソフトウェア、および新しいデジタルコントローラと信号調整器に置き換えることができます。
This issue of TechNotes includes an article on Project 2.6g 329m/s. It also contains a Technical Tip on Keep it Consistent and a question with answer "Q: What is a durometer? Is it an instrument or a measurement?".
Instron® hydraulic wedge grips provide an innovative solution for high capacity testing and deliver enhanced gripping performance, usability, and operator safety.
Accessories for CEAST Drop Tower and Pendulum Impact Testers.
This issue of TechNotes includes an article on the Graphene - The Miracle Material?. It also contains a Technical Tip on Event Log Files and a question with answer "Q: Some Bluehill® calculations don’t show a result when I think they should. Where can I find information on the calculations?".
キャピラリーレオメーターシステムを選ぶ際には、材料の流動に要する最大荷重を評価することが非常に重要です。
棒材/ダンベルからパイプまで、広範囲なサンプルに対して特定の規格に従って、シャルピー試験、アイゾット試験、引張衝撃試験およびダインスタット試験を行うように設計されています。
Manual for Instron Model 4500 Testing System. [Manual Number: M10-94500-1]
Manual for Instron Model 5588 Load Frame. [Manual Number: M10-25588-1]
Manual for Instron Model 5583 Load Frame. [Manual Number: M10-25583-1]
Manual for Instron Model 4483 Load Frame. [Manual Number: M10-24483-1]
Manual for Instron Model 4468 Load Frame. [Manual Number: M10-24468]
Manual for Instron Series 4460 Table-Top Load Frames. [Manual Number: M10-24400-1]
Manual for Instron Series 4200 Load Frames Model 4210. [Manual Number: M10-24210]
Manual for Instron Series 4200 Load Frames Model 4206. [Manual Number: M10-24206-1]
Manual for Instron Universal Testing Instruments Models 4505 and 4507 Load Frames. [Manual Number: M10-4500-5]
Manual for Instron Universal Testing Instruments Models 4210 and 4202. [Manual Number: M10-4200-1(D)]
Manual Instron Universal Testing Instrument Model 1137. [Manual Number: M10-1137-1]
Manual for Instron Universal Testing Instrument Model 1135. [Manual Number: M10-1135-1]
Manual for Instron Universal Testing Instrument Model 1130. [Manual Number: M10-1130-1(B)]
Manual for Instron Model 5568 Load Frame. [Manual Number: M10-25568-1]
Manual for Instron Model 4488 Load Frame. [Manual Number: M10-24488-1]
Manual for Series 4480 Floor Model Load Frames 4481, 4482, 4484, 4485 [Manual Number: M10-24480-1]
Manual for Models 1127 and 1128. [Manual Number: M10-1127 1128-1(A)]
Manual for Model 1125. [Manual Number: M10-1125-1(C)]
Manual for Model 1123. [Manual Number: M10-1123-1(A)]
Manual for Model 1122. [Manual number: M10-1122-1(B)]
Understand what the true benefits and advantages are of updgrading your existing Instron system with a 5900 EXTEND upgrade.
This issue of TechNotes includes an article on the Importance of Testing in an Ever-Changing World. It also contains a Technical Tip on the Importance of Accurate Alignment and a question with answer "Q. In these days of increased awareness of the environment, why does Instron still use “standby” modes on your systems?".
SGS International Certification Services certifies Instron Corporation Quality Management System meets ISO 9001:2008 requirements. Valid until September 12, 2014
[Manual Number: 10-13-2(TM)]
Featuring a dual test space and long test stroke, HVL Models are designed for high capacity tension, compression, bend/flex, and shear testing.
Featuring a large, single test space and single footprint, LX Models are designed for high-capacity tension, compression, bend/flex, and shear testing.
The newly developed Instron CEAST AlOxide® thermal tester determines the Vicat softening temperature and HDT heat deflection temperature of plastics at temperatures up to 500 °C, allowing measurements to be conducted even on highly temperature resistant thermoplastics such as PEEK. Unlike conventional instruments, which use silicone oil as heating medium and typically offer maximum temperatures of 300 °C, the Instron CEAST AlOxide uses heat-resistant aluminium oxide powder in a fluid bed. The method is expected to be adopted in the relevant European standards in the near future.
Instron® offers advanced material testing products for a diverse range of tests including tensile, compression, fatigue, impact, hardness and structural.
Accessories for Composite Testing
Accessories for Elastomeric Testing
The Instron RX Systems are the result of a partnership between Instron, a leading provider of equipment that evaluates mechanical properties of materials and components and Machine Solutions Incorporated (MSI), an innovative manufacturer of proprietary mechanical solutions for the medical device industry. At the core of the Instron RX Systems are Instron’s 5900 Series universal test frame and MSI’s proprietary segmental compression mechanism. The system can be used to generate standard tensile, compression, flexure, peel data, as well as radial stiffness and radial strength from 12 points of contact with the RX fixture. This data is a critical measurement during expansion and compression of interventional devices.
ISO 14801 “Dentistry – Implants – Dynamic fatigue test for endosseous dental implants” specifies the procedure for fatigue testing dental implants. Dental implants are designed by various manufacturers and are of different geometries and sizes depending on where they are placed within the mouth. ISO 14801 aims to establish a benchmark for in vitro testing of implants to compare different implant designs and geometries. It does not begin to replicate the complex conditions implants are subjected to when implanted within the oral cavity. Instron®’s latest design of the dental implant system is a turnkey solution to meet all of the requirements for ISO 14801 and is ideally suited for use with the ElectroPuls™ E1000 or E3000 test instruments.
This issue of TechNotes includes an article on Geomembranes - Protecting Our Water from Our Waste. It also contains a Technical Tip on Accurate Testing Starts with the Preload and a question with answer "Q. How can I be sure that, when I update or upgrade my Bluehill software, the results I’m getting with the new product are the same as the results I was getting with the old one? ".
Instron® Industrial Series Compression Platens are designed to maximize compression testing performance. These high-strength, versatile platens are available in both plane and self-aligning models, and can be easily configured with Instron and other static universal testing machines.
ComplianceBuilder(tm) (CB) is an add-on compliance solution integrated with Bluehill software that provides features necessary to meet the latest FDA 21 CFR Part 11 regulations. This document describes the features in CB that allow you to comply with 21 CFR Part 11; and the associated risks of non-compliance.
5960ツインコラム卓上モデル試験機は50kNまでの広範囲な荷重アプリケーションに使用することができます。様々なロードセルが用意されていますので、ミクロンサイズの繊維の試験からロードフレームの全容量を使用する試験までのアプリケーションにおいて正確に測定することができます。一般にプラスチック、金属、ゴム材料、自動車部品、複合材料、接着剤などに使用されます。
5940シングルコラム卓上モデル試験機は2kNまでの広範囲な荷重アプリケーションに使用することができます。コンパクトな作業空間で高い操作性を提供します。アプリケーションには、医療機器、生体材料、繊維、エラストマー、食品、小さなコンポーネント、ワイヤ、紙、プラスチック、フィルムなどが含まれます。
This issue of TechNotes includes an article on Advances in Crash Testing. It also contains a Technical Tip on Controlling Your Chamber and a question with answer "Q. My specimen is very compliant and I cannot get it to run a fatigue test in load control. What can I do".
New motorized pendulum impact testing system for increased productivity and operator safety
Versatile Grips facilitate loading of large specimens, deliver enhanced gripping performance.
With the new Bluehill® 3 materials testing software, Instron introduces an updated and enhanced version of its proven and widely acknowledged software for measurement, test control and report generation in the determination of the mechanical properties of materials, structures and components.
ASTM D 4255 describes both 2 Rail and 3 rail methods of determining the in-plane shear strength of a composite laminate panel. In the 2 Rail test (Method A) a laminate panel specimen is clamped between loading plates and yokes and then subject to shear loading. Measurement of shear strain requires the use of strain gauges on the specimen.
ASTM C 273 describes a method of determining the shear strength of a sandwich core panel. The test the specimen is bonded to thick loading plate blocks and is subject to shear loading applied via the blocks.
The Iosipescu shear test is used to determine the shear properties of composite materials. Depending on the orientation of the specimen relative to the coordinate system of the material (i.e. the fi ber lay-up either in-plane or interlaminar shear properties can be determined). These shear properties can include: shear modulus of elasticity,transition strain, and ultimate shear stress and strain.
Interlaminar shear testing is a simple test on, easy to prepare,polymer composite specimens that gives a measure of the strength of the bond between fibers and matrix. Another common test for polymer composites is fl exure testing. The Instron® Modular Flexural and Interlaminar Shear Strength (ILSS) bend fi xture system, with a range of interchangeable anvils, is suitable for testing to a number of international standards, including ASTM D2344, D790, EN 2562, EN 2563, ISO 14125, and ISO 14130.
The “Airbus CAI” fi xture is used to test the impact resistance of carbon and other fi ber-reinforced plastic (CFRP) composite laminates. These materials are prone to great reduction in compressive strength even when the impact load is insuffi cient to cause visible damage. The post-impact compression test is used widely to assess the relative performance of different composite laminates with different fi ber matrix combinations. In the fi rst part of the test the laminates are subjected to low-velocity impact loading simulating tool drops and fl ying debris. Specimens then undergo a compression after impact(CAI) test on an electromechanical or servohydraulic testing machine.
ASTM D 1781 describes a method of measuring the strength of the adhesive bond between the core and the facing of a honeycombcore panel. The Instron® climbing drum peel fixtures meet the requirements of ASTM D 1781. Designed with a standard fitting, they can be used on any standard Instron machine. The fixtures are robust and durable, and can be used inside an environmental chamber over a wide temperature range.
The anti-buckling fixture was originally designed for rigid plastics per ASTM D 695, reinforced plastics per ASTM D 3846. It was also extended and used for high-modulus composites. Boeing then adapted the fixture so that it would be self supported between two platens to ensure consistent perpendicularity of the fixture. The SACMA standard followed the Boeing design with an added alternative support fixture with a cutout, which would allow bonded strain gages to be used at the center of the specimen for a more precise strain measurement.
Compression testing of composites without anti-buckling guide plates, is often preferred as the free unsupported length is more representative of true compression behavior. This method relies on the accuracy of the alignment between the upper fixture and the lower fixture while introducing the compression load. In addition, the natural failure process of the specimen will induce high lateral forces that must be resisted to ensure that forces remain in true compression. Therefore, the principle behind the IITRI, Wyoming Modified Celanese and Combined Loading Compression fixtures is essentially the same. Where they are different, is the way the compression load is being introduced – either by shear transfer from jaw faces to specimen, or a combination of shear and end loading. This is the primary difference with the CLC fixture where the shear load component is from the tightening of the screws which is combined with end loads introduced directly. The IITRI and Celanese rely on the self tightening effect from the wedge jaw faces. The Celanese fixture also allows for preloading the jaw faces by manual screws when the specimen is being installed, while the IITRI also includes end bars that could be used to introduce end loads to the specimen. In terms of usability, the IITRI allows the largest specimens, up to 38 mm wide, but is the heaviest of the fixtures. The CLC is conceptually the simplest but care must be exercised to ensure the specimen is properly located and improper or uneven tightening of the clamping screws can affect results. The Celanese is a neat compact fixture but is limited to only 12.7 mm (0.5 in.) wide specimens.
ASTM C 297 describes a method of determining the bond strength between the facing and core of a sandwich core panel or the strength of the core itself, if the bond strength between the facing and the core is suffi ciently strong. The specimen is bonded to thick loading blocks and then subject to tensile loading applied via the blocks.
The MFX 500 is a high-resolution, automatic contacting extensometer that may be used to measure modulus, offset yields, and plastic (non-proportional) elongation to failure for many types of specimens. Automatic control is facilitated using Bluehill® 2 Software, and allows the operator to open and close the arms, set the reference arm position, along with the gauge length.
Screw side-action grips provide a very simple and efficient method for holding test specimens in a wide range of applications. The dual - acting design of 2710-100 series grips means that jaw faces can be adjusted to accommodate different specimen thicknesses. This ensures that the line of tensile force remains concentric with the grip body. They can be equipped with a selection of interchangeable grip jaw faces in various sizes and choice of surfaces including smooth ground, rubber-coated and serrated. Line contact and special coated faces are also available. The unique ‘snap-on’ jaw face attachment makes changing faces extremely quick and simple.
Screw side-action grips provide a very simple and efficient method for holding test specimens in a wide range of applications. The dual - acting design of 2710-100 series grips means that jaw faces can be adjusted to accommodate different specimen thicknesses. This ensures that the line of tensile force remains concentric with the grip body. They can be equipped with a selection of interchangeable grip jaw faces in various sizes and choice of surfaces including smooth ground, rubber-coated and serrated. Line contact and special coated faces are also available. The unique ‘snap-on’ jaw face attachment makes changing faces extremely quick and simple.
Catalog number 2717-069
Describes the test process used to ensure that Bluehill calculations are valid.
Bluehill 3 software is developed using professional standards that are included in this document.
This issue of TechNotes includes an article Full Fluid Jacket – Liquid Body Armor. It also contains a Technical Tip on Don’t Let a Blemished Tup Impact Your Results and a question with answer "Q. When looking at my instrumented impact test data, which result should I focus on more– peak load, energy at peak load, or time to peak load?".
Over the past decade, the medical device and biomaterials industries have undergone tremendous amounts of innovation and change. Materials and technologies have evolved to the point where surgeons are placing small metal stents weighing a few grams into the neurovascular system (in the brain!) to help patients avoid strokes caused by plaque or arterial buildup. Correspondingly, there have been substantial increases in regulatory involvement to ensure safety and efficacy in all devices. These evolutions have translated into a growing requirement for full evaluation of products from concept to product release within the research labs of medical device manufacturers around the world.
A newly developed team of Instron experts focusing on composite solutions for mechanical testing.
A compilation of Instron-grown technical tips, customer interaction around shared problems & solutions, and event updates on where Instron will be and when.
The “Boeing CAI” fixture is used to test the impact resistance of carbon and other fiber-reinforced polymer composite laminates. These materials are prone to great reduction in compressive strength, even when the impact load is insufficient to cause visible damage. The post-impact compression test is used to assess the relative performance of different composite laminates with different fiber matrix combinations. Laminates are subjected to low-velocity impact loading simulating tool drops and flying debris or may be subjected to an out-of-plane static indentation (ASTM D 6264 / D 6264M). Specimens then undergo a compression after impact (CAI) test on an electromechanical or servohydraulic testing machine.
Designed to suit the ElectroPuls™ E10000 Linear-Torsion, the 2742-305 pneumatic wedge-action grips are suitable for tension, compression, reverse-stress, and torsion testing on a wide range of specimens and materials. The grips are pneumatically operated and the open-fronted design provides easy specimen insertion, positioning,and clamping.
Designed to suit the ElectroPuls™ E10000 Linear-Torsion, the 2742-304 pneumatic wedge-action grips are suitable for tension, compression and reverse-stress testing on a wide range of specimens and materials. The grips are pneumatically operated and the open-fronted design provides easy specimen insertion, positioning, and clamping.
インストロン®は、シャルピー規格およびアイゾット規格に対する金属材料試験に大変適した電動式振子型衝撃試験機 MPXシリーズを販売しています。このMPXシリーズは、300ジュールから900ジュールまでの容量で利用可能であり、安全で迅速かつ容易に操作を行っていただけます。このMPXシリーズにはFracra™ソフトウエアが標準装備されているため、エネルギーデータの収集と計算を簡単に行うことができます。また、このシステムでは、Impulse™データ収集ソフトウエアへのアップグレードも容易に行うことができます。Impulse™データ収集ソフトウエアは、荷重および速度変換器を用いてデータの収集、分析、および結果の報告を行います。このMPXシリーズは、CEマーキングに適合しています。
Stents continue to evolve and continued material evaluation and development, as well as the delivery of new testing methods, is important for the evolution and success for these materials.
With a nominal force capacity of 250 N, Instron's pneumatically actuated grips type 2712-019 are particularly suited to testing of biological tissue samples and other specimens made of thin and/or soft materials.
This issue of TechNotes includes an article The Burj Khalifa – Cast in Concrete. It also contains a Technical Tip on Specimen Support in Rockwell Testing and a question with answer "Q. There’s a new acronym in town. What is NADCAP?".
The 5th Edition Accessory Catalog
Bluehill® 3 – Simplicity with Power
この号では、「鉄鋼研究所 (Institute of Research of Iron and Steel、IRIS) 」に関する記事を掲載しています。 「試験片を試験する場合、試験片が降伏しつつある時にひずみ値が後退するようです。伸び計のすべりがこの現象の原因でしょうか。」の質疑応答も掲載しています。
Instron® hydraulic side-acting grips with DuraSync™ technology, are an innovative solution for high-capacity testing and deliver enhanced gripping performance, usability, and operator safety over traditional grip designs. These grips maintain a constant clamping force on the specimen that acts perpendicular to the direction of testing and is independent of tensile loading.
Instron,a division of ITW Ltd, has been assessed and certified as meeting the requirements of ISO 9001:2008.
The Expansion Channel Module, Model 2210-920, allows users to add up to eight channels of signal conditioning and control. As an add-on to a basic 5900 system -- configured for load, extension, and up to three additional channels -- the Expansion Module provides up to a total of 13 transducers for simultaneous monitoring, feedback, and control. (Bluehill® 3 required)
This issue of TechNotes includes an article on composite materials that copy the body’s ability to bruise and self heal when damaged. It also contains a Technical Tip on Perpendicularity in Rockwell Testing and a question with answer "Q. How can I minimize variability when testing stiff materials such as composites?".
This biomedical focused issue includes an article on A New ‘Hip’ Material. It also contains a Technical Tip on Simulating Physiological Conditions of Implants and a question with answer "Q. What testing standards serve as guidelines and requirements for the development and manufacture of hip implants?".
Comprehensive 25-page brochure provides detailed information on all Shore durometer and durometer systems for rubber hardness testing. Features the Shore S1 digital durometer, analog and pencil-style durometers, operating stands, micro-o-ring and IRHD systems, and rubber test block kits.
5980床置き型は、高強度の金属や合金、先進の複合材、航空宇宙および自動車用構造材、ボルト、ファスナー、鋼板材の試験に使用される耐久性に優れた堅牢な構造です。フレームは100、150、250、400、600 kNの荷重容量タイプに加えて、試験空間の延長型(エクストラハイト)や試験空間の幅広型(エクストラワイド)のオプションも用意されています。
ElectroPuls™は単相電源のみで駆動でき、従来の油圧サーボ技術とは異なった環境への影響が少ない、全く新しい疲労試験機です。作動油、三相電源、冷却水が不要です。製品の概要をご覧いただき、お客様の試験環境でElectroPuls™をどのようにご活用いただけるかご検討ください。
9300シリーズ、落錘式衝撃試験システムは、完成製品から特定の規格に準拠して作成された試験片までの広範囲なサンプルの試験が可能です。
The 300/400/600 kN Pneumatic Wedge Action Grips feature an open front design, which facilitates easy loading of large specimens - either round or flat. These grips can be used with the SATEC™ Series LX and KN models, as well as 5988 or 5989 electromechanical floor models. An optional adapter kit offers a solution for mounting compression accessories without uninstalling the grips.
When a testing system is subjected to a force, the entire system (frame, load cell, grips, etc.) deforms. The process of removing this deformation -- leaving only the results of the deformation of the specimen, is fully described in this whitepaper.
This issue of TechNotes includes an article on Growing Your Own Packaging. It also contains a Technical Tip on Automation: Going Automatic and a question with answer "Q. How Do I Reduce Durometer Hardness Test Variability?".
Short description of the innovative Instron® line of CEAST SmartRHEO Series of Capillary Rheometer systems for an accurate investigation of the rheological properties of polymeric materials.
This issue of TechNotes includes an article on Biomimetic Muscles: New Possibilities From Spider Silk. It also contains a Technical Tip on Rockwell Hardness Testing of Thin Materials and a question with answer "Q. Do I have any options to increase productivity in Brinell Testing?".
The 2910-056 heavy-duty support table is ideal for table top testing instruments. The table provides a stable and level working surface, increases safety, and distributes the weight of the load frame in a uniform manner. Improved ergonomic conditions for users are an added benefit.
Instron® testmaster™ 2 Automated Specimen Handling Systems enable a new dimension in testing productivity. Available as either complete turnkey solutions or installed on existing Instron testing instruments, the unique modular design accommodates tensile, flex, and hardness testing. System configurations consist of either a robot or a carousel for rotary specimen handling. Materials tested include metals, plastics, thin films, components, elastomers, and medical devices.
The Instron® Automated Carousel feeding system is a new approach to handling test specimens. The primary components of the system include a linear feeding system, a rotating specimen storage rack, and a universal testing instrument. The carousel system is ideal for flexible materials, including thin films and flexible tubing. The handling system is a modular unit that conveniently bolts onto a standard 5960 dual column testing system.
Variable rate springs are becoming more common in vehicle suspensions. This application report examines the process of defining the transition point between the load vs. height curve. This information can then be used to refine the spring manufacturing process to produce more consistent product.
Details the importance of accuracy with spring testing.
SRI Quality System Registrar is pleased to announce that it has recently awarded an ISO 9001:2008 Management System certificate to Instron Industrial Products Group, located in Grove City, Pennsylvania, for design, manufacture, recondition, and retrofit of static hydraulic, torsion, spring, creep, and impact instruments, systems, and accessories for tension, compression, and impact testing, including materials testing software.
1000HDX SATEC series universal hydraulic testing system with dual test space design for tension, compression, bend, shear, and flexure testing on high strength materials.
A Compilation of Technical Tips, Questions and Answers, and Customer Features from the TechNotes Newsletter
Operating a 5900 Series testing system is easier and quicker than ever before. By utilizing the many capabilities of the Productivity Panel, users can perform every test function without relying on a mouse--install a specimen and begin testing without ever stepping away from the machine; customize the soft key buttons to initiate a variety of commands; and configure the panel to display real time results throughout the test.
The Instron® Digital Long-Travel (DXL) extensometer is a high-precision device for measuring strains of highly extensible materials such as elastomers, semi-rigid plastics, and films. The DXL is compatible with most electromechanical testing instruments and easily installed on an Instron system.
Are you using your grips to improve your safety and ease of use? How Pneumatic Grips can Help Safety and Ease of Use
The ElectroPuls E10000 Linear-Torsion test instrument is a state-of-the-art, all-electric test system designed for dynamic and static testing on a wide range of materials and components. It features a combined linear-torsion actuator in the upper crosshead and is capable of operating at over 100 Hz. With ±10000 N dynamic load and ±100 Nm torque capacity, it includes the latest in testing technology – patented tuning based on specimen stiffness, electrically operated crosshead lifts, a T-slot table for flexible test set-ups and a host of other user-orientated features. Unlike conventional servohydraulic test systems, it is an all-electric system, powered from a single-phase supply, and requires no additional utilities.
The ElectroPuls E10000 test instrument is a state-of-the-art, all-electric test system designed for dynamic and static testing on a wide range of materials and components. With ±10000 N dynamic load capacity and capability of over 100 Hz, it includes the latest in testing technology – patented tuning based on specimen stiffness, electrically operated crosshead lifts, a T-slot table for flexible test set-ups and a host of other user-orientated features. Unlike conventional servohydraulic test systems, it is an all-electric system, powered from a single-phase supply, and requires no additional utilities.
Are you using your grips to improve your productivity and repeatability? How Pneumatic Grips can Help Productivity and Repeatability
Following is our "Statement of Principles of Conduct" describing the standard of behavior governing all ITW employees and directors. These principles apply to all our business activities around the world.
Organization, Management and Control Model
Instron® 2712-04x シリーズ空気圧式グリップは、グリップ性能、操作性、オペレータの安全性を向上するためのさまざまな性能が盛り込まれています。
Bluehill® 3 は、インストロンのBluehillソフトウエアの最新版です。教育関係から試験担当者、品質管理担当者、実験室の管理者などあらゆるユーザーのご要望に応えられるよう機能の強化が図られています。5900および5500シリーズの試験システムと互換性があります。
This hardness application is to be used as a reference tool for converting between popular scales to find tensile strength, wear resistance, ductibility, and other physical characteristics of metallic materials.
Within the Bluehill User Community Blog, users can gain training tips, search through frequently asked questions, search for solutions to test methods, and post their own questions to the product manager.
材料試験機は、力や変位を測定する計量機器ですので、その計量精度が保証されている必要があります。精度を保証するために、荷重や変位の校正が必要となります。インストロンジャパンが提供する校正サービスをご案内します。(2009年版)
This plastics focused issue includes an article on Green Plastic: The Garbage Dump Killer. It also contains a Technical Tip on Test Specimen Cutting and Stamping and a question with answer "Q. There is too much variability in my Poisson's ratio values, what can I do?".
The SATEC Series Model 600HVL high capacity universal testing machine features a dual test space designed for tension, compression, bend, shear, and flexure testing on high-strength materials.
The manual wedge action grip is designed for easy specimen loading, alignment and positioning. After initial face to specimen contact, gripping force will increase as the testing load increases. Due to Instron®'s design of moving grip bodies, virtually no preload is seen during specimen clamping. This makes them particularly suitable for testing high strength materials, such as metals and composites, ensuring that specimen slippage is eliminated.
This issue includes an article on the The Tower of Babel: Testing the Possibilities. It also contains a Technical Tip on Multi-Purpose Grip Shields and a question with answer "Q. Can I trust my strain figures when they are derived from crosshead position rather than from an extensometer?".
SI-1M 450 Joule Motorized Pendulum Impact Testing Machine for testing metals to Charpy and Izod standards.
Two-page overview of Shore Instruments durometers and durometer systems for rubber hardness testing. Includes descriptions and photographs of analog and digital durometers, operating stands, micro-o-ring systems, and rubber test blocks.
The 2701-221 combined specimen holder and specimen alignment device (patent pending) is an optional item for 2712-041 and 042 pneumatic side-action grips. The spring-loaded grippers hold the specimen while the operator closes the grips prior to starting the test.
Lever arm machine for creep and stress rupture applications that involve maintaining constant loads for extended periods of time. - pod_M3_REV3_1203
This newest version of the popular Bluehill Materials Testing Software provides a wide range of tailored application solutions to meet the demands of any level of user.
New line of universal electromechanical testing systems that are designed with exceptional performance and improved ergonomics, and deliver superior accuracy, reliability, and enhanced overall operator experience.
The Bluehill 3 Plastics Application Module provides a comprehensive platform for measurement, test control, and report creation for testing a wide variety of plastic materials and components. The Plastics Application Module includes a collection of pre-configured test methods and supporting documentation that cover a variety of internationally recognized industry standards such as ASTM D790, ASTM D6272, ISO 178, and ISO 604.
The Bluehill 3 Metals Application Module includes a collection of pre-configured test methods and supporting documentation that cover a variety of internationally recognized industry standards; such as BS EN 10002-1, ISO 6892, ASTM E8, ASTM E21, ASTM E571, ASTM E646, and more.
The Bluehill 3 Adhesives Application Module includes a collection of pre-configured test methods and supporting documentation that cover a variety of internationally recognized industry standards; such as ISO 813, ISO 11339, ASTM D1876, BS EN 1465, BS EN 1719, and more.
The Model C lever arm machine was designed specifically for long term stress-rupture test applications that involve maintaining constant loads for extended periods of time.
The Bluehill 3 Textiles Application Module includes a collection of pre-configured test methods and supporting documentation that cover a variety of internationally recognized industry standards; such as ISO 13934-1, ISO 13934-2, ISO 9073-3, ISO 9073-4, ASTM D5034, and more.
The Bluehill 3 Elastomers Application Module includes a collection of pre-configured test methods and supporting documentation that cover a variety of internationally recognized industry standards; such as ISO 813, ISO 34-1, ISO 37, ASTM D412, ASTM D413, ASTM D1414, and more.
The Bluehill 3 Classroom Edition simulates testing without a testing system. This standalone version of Bluehill software includes a full library of pre-configured test methods and data sets to demonstrate the basic principles of materials science with your students without having to run the tests on your own.
The Bluehill 3 Biomedical Application Module includes a collection of pre-configured test methods and supporting documentation that cover a variety of internationally recognized industry standards; such as EN 455-2, ASTM F2516, ASTM F2256, ASTM F88, and more.
This issue includes an article on the differences between Calibration and Verification, knowing the difference and making sure your lab is investigation ready. It also contains two Q&As, "Can you give me a letter certifying that my test is in accordance with a specific ASTM or ISO standard?" and "What does accreditation mean and how does it affect testing standards?".
Fatigue tester capable of rotating each specimen through an average of 9,999 complete stress cycles per minute.
The Difference Between an Instron® Model 3342 and a Chatillon Model LR5K Plus.
Electromechanical table-top testers provide low to mid range torque loads with multiple rotations up to 220 Nm (2,000 in-lb). pod_55MT_REV3_1203
The 3300 tabletop models have been developed to address the requirements of standardized and routine testing. These models provide the user with Instron quality at the most affordable price. Load capacity from 5 kN to 50 kN with a maximum speed of 1000 mm/min (3365 model). These systems conform to all relevant European standards and carry a CE mark
The 3300 single column models have been developed to address the requirements of standardized and routine testing. These models provide the user with Instron quality at the most affordable price. Load capacity from 0.5 kN to 5 kN with a maximum speed of 1000 mm/min. These systems conform to all relevant European standards and carry a CE mark.
Automatic attaching and detaching extensometer with gauge lengths up to 200 mm. Travel of 300 mm minus the gauge length.
The 3300 floor models have been developed to address the requirements of standardized and routine testing. These models provide the user with Instron quality at the most affordable price. Load capacity from 100 kN to 250 kN with a maximum speed of 500 mm/min. These systems conform to all relevant European standards and carry a CE mark.
This hardness-focused issue includes a technical tip on "Increasing Efficiency in Knoop and Vickers Testing", a technical tip on "Best Practices: Which Rockwell Scale to Use" and a Q&A on "Q: How far apart should I space each Rockwell hardness test?"
Testing at Non-Ambient Temperatures
Manual for Instron models 5941, 5942 and 5943 electromechanical systems.
SATEC Series 400HVL Model Universal Testing Machines feature a dual test space design for static tension, compression, bend/flex, and shear testing. These frames use hydraulics to cost-effectively provide the forces necessary for testing and represent some of the most rugged and durable machines ever made.
This biomedical-focused issue includes an application story on "Study Show Differences in Mesh Materials for Hernia Repair", a technical tip on "Challenges in Testing Biomedical Components" and a Q&A on "How should I best address challenges in testing various geometries of medical devices and implants?"
アプリケーションノート:若い頭脳のための材料科学/テクニカルヒント:高温または低温での試験/質問と回答:3点曲げ試験と4点曲げ試験の違いは何ですか?
This issue includes technical tips on "Why Alignment is Important in Tensile Testing" and "Hardness Testing on Cylindrical Specimens". The Q&A is on "How do I deal with Toe Compensation?"
操作性や安全性を改善した新しい2712-04xシリーズ空気圧式サイドアクショングリップ
2580 Series Static Load Cells are precision force transducers and an integral part of an Instron universal testing system. Force capacities range from +/- 500 N to +/- 600 kN (50-60,000 kgf or 112-137,000 lbf).
Instron® is the premium choice for reconditioned equipment. This literature describes the reconditioning process and features of a Reconditioned Electromechanical System.
Instron® is the premium choice for reconditioned equipment. This literature describes the reconditioning process and features of a Reconditioned HVL Series.
Designed for high-capacity tension, compression, bend/flex, and shear testing, the 1500HDX Model is powered by a hydraulic pumping system that moves a piston assembly to provide the forces necessary for testing.
食品試験用アクセサリー:Kramerせん断セル/Ottowaテクスチャー試験治具/トルティーヤ/ペストリーバースト治具/マルチ突き刺し治具/試験プロファイラなど
The XY Test Stage is useful for testing components, sub-assemblies, or end products that have multiple elements or leads that need to be tested independently of one another; commonly found in the medical device industry. Mounts to most universal testing instruments.
The component test plate is a large plate with an array of tapped holes that is useful for securing difficult-to-test components for a variety of tensile, compression, peel or other testing. It can be used with most universal testing systems.
The Syringe Test Fixture is designed to meet the test requirements of ISO 7886-1 Annex G for sterile, single-use hypodermic syringes. It can easily be mounted to most universal testing systems.
アプリケーションストーリー:さまざまな試験条件で品質を保証する/テクニカルヒント-1:衝撃試験を計装化した方がよいのはなぜでしょうか?/テクニカルヒント-2:実行中の試験をキャプチャする
The MFX 500 automatic contacting extensometer is a universal, high-resolution extensometer with a rugged construction that makes it suitable for almost any application that requires the measurement of linear strain.
Packed with features to enhance usability, safety, productivity, and repeatability of test results, the pneumatic grips are available in capacities of 1 kN, 2 kN, 5 kN and 10 kN.
The ElectroPuls™ E10000 and E10000 Linear-Torsion are innovative all-electric dynamic test instruments capable of up to 10,000 N (2250 lbf). The E10000 Linear-Torsion features a patented and combined linear-torsion actuator for bi-axial tests of materials and components.
Solutions for Automated Hardness Testing
Overview of Wilson Instruments Tukon 2100B, Microhardness tester for Knoop and Vickers testing. Includes detailed specifications, capabilities and recommended options.
High-Stiffness Support Table for ElectroPuls E1000 and E3000 tabletop test instruments.
The Wilson Instruments 574 Rockwell Testers are proven, durable, and reliable performers meeting a range of Rockwell testing applications. Available in Regular, Superfi cial or Twin Scale models, the 574 provides a rugged industrial design, an all-new, easy-to-use control panel, and a built-in USB for easy data transfer to Microsoft® Excel® or other applications. Designed with the best repeatability in its class, the 574 is an affordable, high-precision depth measurement system with proven performance.
Overview of Wilson-Wolpert Digital Microhardness Series 402MVD testers.
The Wilson Instruments TESTOR 930, with its user-friendly operator panel, displays hardness values for all common hardness test procedures. The closed-loop load system eliminates overshoot and combines a fully-automatic controlled test cycle with a broad load range from 1 - 250 kgf. The quick access buttons allow operators access to 99 different test programs for all hardness scales (HR, HB, and HV). In compliance with ISO standards, each program can be set up with user-defined test parameters including test force, application time,conversion, and shape correction. The intuitive user interface and one-touch operation ensures an efficient and reliable test process, while the interchangeable objectives, which range from 20 - 140X, allows for testing a variety of applications.
テクニカルヒント-1:上降伏が見えないのはなぜでしょうか?/テクニカルヒント-2:高強度の鉄筋の試験/質問と回答:薄い金属の試験片にはどのグリップが適しているでしょうか?
疲労試験用グリップ:低荷重用グリップ/疲労試験とは?/なぜ疲労試験を行うのでしょうか?
RS LabSite modulogicは、従来のRS LabSiteに代わる次世代のソフトウェアです。コンポーネントまたは実車の実働入力データを使用した試験、およびバーチャル試験ソフトウェア上のモデルでの計算によるシミュレーション用に考案された、柔軟性のある統合ソフトウェアパッケージです。<カタログNo.:IST0070AG-JA> 2009年6月版
Pneumatic Adhesive Shear Test Fixture per ISO 13007-2
The Syringe Test Fixture evaluates the performance of needles or syringe/needle combinations.
テクニカルヒント:最高品質の試験結果は得られていますか?/質問と回答:太陽電池の機械的試験は、「グリーンエネルギー」イニシアチブにどのように貢献しているのでしょうか?
試験片アライメントの最適化:ユニバーサルカップリング、球面座圧縮プラテン、AlignPro™ システムなど
Detailed description of fixture that is designed to evaluate the performance of syringes and syringe/needle combinations. Primary uses are determining breakaway forces at the beginning of injections as well as sustaining forces throughout the injection process.
テクニカルヒント:プラスチックを測定する際の注意/質問と回答-1:ポアソン比の測定精度と再現性はどうしたら改善できるでしょうか?/質問と回答-2:熱可塑性プラスチックを試験するとき、クリップオン伸び計がひずみ測定結果に影響を与えてしまうことはあるでしょうか?
3300シリーズ試験機は、製品開発や品質管理に必要とされる各種試験を実施するために開発されており、シンプルかつ充分なパフォーマンスを備えています。お客様にとって、最もお求めやすい価格で、インストロンのソリューションをご活用いただけます。
3300シリーズ万能試験機の寸法・重量・容量・消費電力等の主な製品仕様(2009年3月)
ウェブサイトの新しいコンテンツ:試験ソリューション/テクニカルヒント:データ速度とは?
生体医学アプリケーション用アクセサリー - Part 2:BioPuls SVE(標準ビデオ伸び計)を使った縫合糸試験ソリューション/コンタクトレンズ試験ソリューション/BioPuls Dual-Station ISO股関節シミュレータ など
Indicating Resin Acrylic-Bonding-Potential for Tub and Shower Laminates
FDA 21 CFR § 11 Regulations Software Solution – Bluehill® ComplianceBuilder™
アプリケーションノート:低荷重での試験に最適なグリップ方法/質問と回答-1:医療機器産業ではどんな種類の国際試験規格が使用されているのでしょうか?/質問と回答-2:21 CFR Part 11とはどのようなものでしょうか?
Testing Equipment Company Complements Instron® Product Line
Joseph Amaral, Instron’s retired President, was awarded The John M. “Tim” Holt Lifetime Achievement Award from the ASTM Committee E28.
Catalog Number 2810-005 Allows precise measurement of the static and kinetic coefficient of friction.
Services for the aerospace and automotive industries.
This 4th Edition catalog is designed with a new look and feel - offering full color images of the broad range of materials testing accessories.
The 9250HV-HT is ideal for impact tests on athletic or industrial helmets, as well as performing shock attenuation and force transmission tests.
Summary of 5500A Series dual column tabletop systems product enhancements and technical specifications.
Summary of 5500A Series single column tabletop systems product enhancements and technical specifications.
アプリケーションノート:素敵な笑顔を支える試験/テクニカルヒント:オペレータが変わると試験結果が変わりますか?/質問と回答:精度と分解能とはどういう関係でしょうか?
These automated testing systems offer advantages over traditional, manually-operating testing systems, including improved productivity and increased volume of specimens tested.
The 2820 Series of wood bend fixtures are designed in accordance with common International Standards for performing flexure tests on a range of wood products.
Instron® is the premium choice for reconditioned equipment. This literature describes the reconditioning process and features of a Reconditioned BTE Series.
環境槽での使用(-100℃~+200℃)にも適したクリップオン伸び計。幅広い範囲の試験に対応できる豊富なラインナップ。また、正負両方のひずみを測定できるので、圧縮や曲げ試験でのひずみ測定も可能です。 [2008年11月版]
生体医学アプリケーション用アクセサリー - Part 1: 軟組織に対する高性能ビデオ伸び計(AVE)でのマーキング手法/高伸度伸び計を使った外科用薄肉チューブの引張試験/皮下注射針の引張試験 など
アプリケーションノート:計装化衝撃試験がポピュラーになっている事情/質問と回答-1:衝撃試験の荷重曲線で第1ピークが発生するのはなぜでしょうか?/質問と回答-2:衝撃試験にはどれくらいのエネルギーを使用すればよいのでしょうか?
This add-on compliance solution, which can be integrated with Bluehill® Software, meets regulatory guidelines found in FDA 21 CFR Part 11.
ソフトウェアを強化する新モジュール。Bluehill 2 ビデオ&プレイバックモジュール/WaveMatrix計算モジュール(DMA)
Solutions for Biomedical Testing presents a wide range of examples and application solutions for medical devices, biological tissues, biomaterials, orthopaedic devices, hip implants, knee implants, spine, fixation devices, dental materials and implants, and biomechanics such as athletic footwear.
The latest changes to the ASTM E18 standard require suppliers to verify the performance of ball indenters to meet E18-07 and later compliance.
Latest changes to the ASTM E18 standard require suppliers to verify the geometry of indenters to meet E18-07 and later compliance.
The latest changes to the ASTM E18 standard require users to use E18-07 or later compliant test blocks for hardness testing.
The 2601 series Linear Variable Differential Transformer (LVDT) displacement transducers are measuring devices that measure the displacement of the load frames of materials testing systems. They feature an LVDT as the active element, and are designed for use on both electromechanical and hydraulic Instron® testing systems.
Catalog number 2714-004 Rated capacity 1 kN (100 kgf, 225 lbf) Suitable for a wide range of linear densities (denier and tex)
Catalog number 2714-006 Rated capacity 1.6 kN (160 kgf, 350 lbf) Suitable for a wide range of linear densities (denier and tex)
The Instron capacitive extensometer measures small changes in length of test specimens at very high temperatures. It has been developed in conjunction with a number of advanced programs throughout the world investigating the properties of materials including alumina, silicon carbide, silicon nitride, carbon/carbon composites and other advanced ceramics.
Brochure that promotes temperature calibration on environmental cabinets and similar thermal equipment undertaken by Instron's European Calibration laboratory.
テクニカルヒント(特別編):非接触式ビデオ伸び計のメリットに関する調査結果
The paper provides an overview of 21 CFR Part 11 as it pertains to materials testing, electronic records, and electronic signature procedures for industries regulated by the U.S. Food and Drug Administration (FDA). It describes the key elements of 21 CFR Part 11 and provides a methodology for transitioning your lab to a 21 CFR Part 11 compliant laboratory.
金属試験に使用するアクセサリー - Part 2
Gage repeatability and reproducibility, also known as GR&R, is a type of statistical analysis that is often performed by quality and product engineers as a method of test equipment validation and verification. The purpose of this paper is to highlight a variety of error sources, and provide suggestions and guidelines for conducting a successful GR&R study.
Manual for Model 4411. [Manual Number: M10-24411-1]
Manual for MN44 and MN 55 load frames. [Manual Number: M10-2MN44-1]
Manual for Model 1011. [Manual Number: M10-21011-1]
Manual for Model 4510. [Manual Number: M10-24510-1]
Manual for Model 4204. [Manual Number: M10-24204-1]
Manual for Models 4201 and 4202. [Manual Number: M10-24201-1]
金属試験に使用するアクセサリー - Part 1
テクニカルヒント:適切なグリップアクセサリの使用による試験機の保護/質問と回答:降伏応力の測定には、どのように伸び計を選べばよいでしょうか?
Instron Pty's Calibration Laboratory is accredited to ISO 17025 for Force and Extension by the National Association of Testing Authorities (NATA), Laboratory Number 3037. NATA holds the original of the certificate on their site at: http://www.nata.asn.au/
Properly managing your database can speed up data retrieval. This webinar will discuss the Data Manager Tool and how to use Partners Access and Excel Reporting Tools.
動的・疲労試験用WaveMatrix™ソフトウェアのご紹介
FDA Compliance Statements
現在お使いのインストロン4200/4400シリーズ試験機のコントローラを、最新の3300コントローラとソフトウェアにアップグレード。使い慣れた試験機本体はそのままご使用いただけます。
テクニカルヒント-1:引張試験片をクランプした後に荷重が負の値になることがあるのはなぜでしょうか?/テクニカルヒント-2:硬さ試験機:閉ループ式?それとも重錘式?/質問と回答:パイプや円筒のねじり特性はどのように測定することができるでしょうか?
Instruction Manual for Series 500 digital testers.
Instron's 9250 drop tower measures energy absorption and impact properties of polymers, metals, composites and more.
Accreditation Germany IS0 9001
Instron's 3300 single column testing system is ideal for medical device testing, and is engineered to cover a range of testing from 500 N to 5 kN.
The RX 550 & RX 650 Systems are the result of a partnership between Instron, a leading provider of equipment that evaluates mechanical properties of materials and components, and Machine Solutions Incorporated (MSI), an innovative manufacturer of proprietary mechanical solutions for the medical device industry. The RX Systems are primarily used for the radial compression of interventional devices, including: balloon expandable stents, self-expanding stents, stent graft products, collagen plugs, embolic filters, vena cava filters and other basket type filter products.
テクニカルヒント:試験片の正しい標点距離の指定/テクニカルヒント:低温環境槽でのグリップの使用/質問と回答:試験中に突然電源が切れたらどうなるのでしょうか? Bluehill® のデータはすべて失われてしまうのでしょうか?
5587型/5589型試験機は、大容量に対応するフレームとデジタル制御のコントローラを備えた材料試験システムです。<2003年12月版>
プラスチック・ゴム・金属材料や製品、コンポーネントの試験に適した材料試験機および治具やソフトウェアをパッケージ化し、日本での販売を開始。
クリーンなリニアモーター駆動の材料試験機を新開発。
NPL(イギリス国立物理研究所 )と共同で開発した電熱試験試験システムETMT 8800を市場投入。ETMTは通電加熱システムを備え、3kNまでの引張圧縮負荷と1500℃までの加熱能力を提供。金属などの導電性材料の試験に最適。
接着剤の試験で使用するアクセサリー
Bluehill 2材料試験ソフトウェア優待販売のお知らせ
複合材料の試験で使用するアクセサリー
繊維の試験で使用するアクセサリー
エラストマーの試験の試験で使用するアクセサリー
アプリケーションストーリー:強い構造:不安定な地盤でも高い安定性を得るための構造材料の試験/質問と回答:試験機で弾性率の値が低く得られるのはなぜでしょうか?
アプリケーションストーリー:不沈艦/テクニカルヒント:ウェッジグリップの締付け/質問と回答:ASTMとISOの違いはなんですか?手持ちの試験治具は使えるでしょうか?
アプリケーションストーリー:隠れたセンサーが安全を高める/テクニカルヒント:お客様のアプリケーションにはツインコラムのロードフレームが必要でしょうか?/質問と回答:インストロンは各種試験アプリケーションの参考資料などをオンラインで提供しているでしょうか?
アプリケーションストーリー:優れたインプラント開発のための背骨の運動の特性評価/テクニカルヒント:グリップフェースは磨耗していませんか?/質問と回答:伸び計の使用準備が完了したことは確認できるのでしょうか?
アプリケーションストーリー:品質の音/テクニカルヒント:コンプライアンスの補正/質問と回答:クリップオン伸び計を使う場合に、より正確なr値を測定するにはどうしたらよいでしょうか?
アプリケーションストーリー:超人的パワーに潜むサイエンス/テクニカルヒント: グリップアタッチメント技術/質問と回答:試験片グリップ時に荷重が負の値になることがあるのはなぜでしょうか?
アプリケーションストーリー:CO2 から硬い岩石へ/テクニカルヒント:ロードセルのバランスをとってはいけないケース/質問と回答:どんな種類の伸び計を使えばいいのでしょうか?
アプリケーションストーリー:実験室培養の組織/テクニカルヒント:タップの破損が結果を変える/質問と回答:静的試験機で繰返し試験を実行したいのですが、どれくらいの速度が可能でしょうか?
アプリケーションストーリー:最近の研究でタイタニック号のミステリーが明らかに/テクニカルヒント:Bluehill® ソフトウェアの初期荷重機能の利点/質問と回答:各試験片ごとに寸法を入力する必要はあるのでしょうか?
アプリケーションストーリー:動脈内部で起こっていることは?試験で脳卒中の危険性を暴く/テクニカルヒント:空気圧式グリップで、より早く、より安定した試験を/質問と回答:引張試験では、なぜ材料ごとに降伏後の速度を変えるのでしょうか?
プラスチックとポリマーの試験で使用するアクセサリー
常温以外の温度環境下での試験/環境槽と加熱炉の使用上のアドバイス/常温以外の環境における非接触式ビデオ伸び計
食品の試験で使用するアクセサリー
各種材料や製品に対する使用環境要求は、ますます厳しくなっています。これらの材料および製品の性能を充分に理解、あるいは検証するためには、高低温度に対応する試験ソリューションが必要です。インストロンの3119シリーズ環境槽は、正確に制御された温度環境のもとで、最先端の材料試験を実施することが可能です。
Dynatup 9200シリーズ衝撃試験システムは、高性能な試験フレーム、高度なデジタル信号処理エレクトロニクス(DSP)、自己認識機能をもつロードセル、そして制御とデータ収集を行うImpulseソフトウェアで構成されています。低エネルギーから高エネルギーまで、広範囲の衝撃試験に対応します。
高性能ビデオ伸び計(AVE)は、高解像度デジタルカメラとLEDライトを使用し、非接触でのひずみ測定を実現しています。高度なリアルタイム画像処理技術により、試験片の正確な軸方向および横ひずみ測定が可能です。非接触のため、「試験片に影響しない」、「可動部の慣性によるエラーがない」、「試験片破断時のエネルギー開放による伸び計損傷の危険がない」など、従来の接触式伸び計では実現できない多くの利点があります。
The Pneumatic Marking Station quickly and accurately applies dot targets to test specimens prior to testing with an Instron® non-contacting video extensometer.
The Hand-Operated Marker provides a means for easy specimen marking for video extensometers. Apply optimal size marks to your specimen with consistency and speed.
WaveMatrix™は、材料やコンポーネントの動的および疲労試験用のソフトウェアです。単純な静的ランプ波形から繰返し波形、そして、複雑なマルチステップ試験や多軸試験まで、さまざまな試験を実行できます。直感的でわかりやすいビジュアルな操作環境備えています。
W-E402 Series Averaging Axial Extensometers are ideally suited for testing a wide range of materials, including advanced composites. Two independent strain sensors measure axial displacements from opposite sides of the specimen and produce a single averaged output.
W-E404 Series Transverse Extensometers are designed for measuring transverse displacements. They are self-supporting on the test specimen and will work on any width or diameter specimen from 0 to 25 mm(1 in).
W-E440 High-Temperature Series extensometers are ideally suited for testing materials such as advanced composites, metals and polymers at elevated temperatures. They incorporate a capacitive sensor that does not require any cooling.
W-E404-D Transverse Averaging Extensometer is specifically designed for measuring the transverse displacements used in determining the r-value in sheet metal testing.
W-E402 Series Biaxial extensometers are ideally suited for testing anisotropic materials such as advanced composites as well as for general purpose tests such as determining Poisson’s ratio.
This webinar defines Modulus, describes the different modulus calculations available in Bluehill, and describes the slope calculations.
3300 Single Column Medical Device Testing Systems. A wide range of solutions to address a variety of biomedical applications from sutures, needles and tubing, to medical packaging and gloves, is offered by Instron.
Upgrade Solutions for Universal Hydraulic Testing Systems.
Instron®'s world class training is the measurable difference in operating more efficiently, reliably and safely.
Web Support Agreement - where service and value come together - assists you in running better, faster, cheaper and safer.
インストロンの Bluehill Lite 材料試験ソフトウェアは、標準化された引張・圧縮・曲げ・剥離・引裂き・摩擦試験、および簡単な繰り返し試験で必要とされる機能を備えています。すべてのインストロン3300シリーズシステムでご利用いただけます。
Displacement calibration services
The Web Support Agreement with a three-month free trial offer
インストロンの会社概要、歴史、製品、その品質等をご紹介しています。<カタログNo. WB1168C-JA> 2007年9月版
The 2810-412 miniature 3-point bend fixture is designed for Mode II fracture toughness testing. The fixture fully complies with the requirements of SEMI standard G69-0996 ‘Test method for measurement of the adhesive strength between lead frames and molding compounds for semiconductor packages’.
Calibration is often required by an organization's internal quality standards or by international or national standards or laws. Instron calibrates most types and brands of materials testing machines. Instron calibration's quality and aceptance is demonstrated by its NVLAP (North America); UKAS and DVD (Europe); NATA (Asia and Australia) and KOLSA (Korea) accreditation.
Used to test carbon and aramid fiber reinforced plastic (CFRP) composite laminates. Conforms to Boeing BSS 7260/ NASA CAI Catalog Number 2505-003
Instron Extra is the flexible service option that can provide total testing support. It is important that you obtain the best possible performance from your materials testing systems whether they are new, upgraded or non-Instron systems. Instron Extra is designed for realizing the potential of your testing equipment.
Catalog Number 2714-031 Rated capacity 50 kN (5 kgf, 11 lbf) Suitable for a wide range of linear densities (denier and tex)
Low Cycle Fatigue 3 (LCF3) offers a flexible workspace designed to run and analyze strain controlled fatigue tests in accordance with ASTM, ISO and BS standards.
Instron's R.R. Moore is ideal for use in classrooms and labs.
Application report on testing per ASTM E 436; ASTM e 604 & API-5L
Application report detailing impact testing per ASTM D-3763
Application report detailing testing per ISO 6603-2
Application report describing impact testing of compososite decking materials.
Bluehill 2 材料試験ソフトウェアは、ホームページのような直感的なインターフェースを備え、優れた操作性を提供します。ASTM、ISOなどの各種試験規格に準じた試験を簡単に実行できるほか、独自のパラメータによる試験にも対応可能です。またMS WordやExcelへのデータのコピー&ペーストや、PDF形式でのレポート出力もでき、高機能で使いやすい最新のソフトウェアです。
Changes to ASTM Standards in 2007 E18 Rockwell and E10 Brinell
Accreditation 2007 10 CFR Part 21 is the US Code of Federal Regulations for the Nuclear Industry.
PACKAGING MATERIALS AND SYSTEMS FOR MEDICAL DEVICES WHICH ARE TO BE STERILIZED – PART 5: HEAT AND SELF SEALABLE POUCHES AND REELS OF PAPER AND PLASTIC FILM CONSTRUCTION – REQUIREMENTS AND TEST METHODS
CONDUIT SYSTEMS FOR CABLE MANAGEMENT – PART 2-4: REQUIREMENTS FOR CONDUIT SYSTEMS BURIED UNDERGROUND
MEDICAL GLOVES FOR SINGLE USE – PART 2: REQUIREMENTS AND TESTING FOR PHYSICAL PROPERTIES (INCLUDING TECHNICAL CORRIGENDUM 1996)
SELF ADHESIVE TAPES – DETERMINATION OF PEEL ADHESION PROPERTIES
ADHESIVES FOR PAPER AND BOARD, PACKAGING AND DISPOSABLE SANITARY PRODUCTS – TACK MEASUREMENT FOR PRESSURE-SENSITIVE ADHESIVES – DETERMINATION OF LOOP TACK
PLASTICS - DETERMINATION OF TENSILE PROPERTIES – PART 2: TEST CONDITIONS FOR MOULDING AND EXTRUSION PLASTICS
TEXTILES – TEAR PROPERTIES OF FABRICS – PART 2: DETERMINATION OF TEAR FORCE OF TROUSER-SHAPED TEST SPECIMENS (SINGLE TEAR METHOD)
TEXTILES – TENSILE PROPERTIES OF FABRICS – PART 2: DETERMINATION OF MAXIMUM FORCE USING THE GRAB METHOD
TEXTILES – TENSILE PROPERTIES OF FABRICS – PART 1: DETERMINATION OF MAXIMUM FORCE AND ELONGATION AT MAXIMUM FORCE USING THE STRIP METHOD
TISSUE PAPER AND TISSUE PRODUCTS – PART 4: DETERMINATION OF TENSILE STRENGTH, STRETCH AT BREAK AND TENSILE ENERGY ABSORPTION
PACKAGING – SACKS MADE FROM THERMOPLASTIC FLEXIBLE FILM – TEAR PROPAGATION ON EDGE FOLDS
ADHESIVES – T-PEEL TEST FOR FLEXIBLE-TO-FLEXIBLE BONDED ASSEMBLIES
FINAT TEST METHOD NO. 22 INK ADHESION - ADVANCED
FINAT TEST METHOD NO. 9 ‘LOOP’ TACK MEASUREMENT
FINAT TEST METHOD NO. 3 LOW SPEED RELEASE FORCE
FINAT TEST METHOD NO.2 PEEL ADHESION (90º) AT 300mm PER MINUTE
FINAT TEST METHOD NO. 18 DYNAMIC SHEAR
FINAT TEST METHOD NO. 11 QUALITY OF SILICONE COATED SUBSTRATES FOR SELF-ADHESIVE LAMINATES: SUBSEQUENT ADHESION
FINAT TEST METHOD NO.1 PEEL ADHESION (180º) AT 300mm PER MINUTE
FINAT TEST METHOD NO.1 PEEL ADHESION (180º) AT 300mm PER MINUTE
TOUCH AND CLOSE FASTENERS – DETERMINATION OF PEEL STRENGTH
ADHESIVES – DETERMINATION OF TENSILE LAP-SHEAR STRENGTH OF RIGID-TO-RIGID BONDED ASSEMBLIES
TEXTILES – TEAR PROPERTIES OF FABRICS – PART 4: DETERMINATION OF TEAR FORCE OF TONGUE-SHAPED TEST SPECIMENS (DOUBLE TEAR TEST)
TEXTILES – TEST METHODS FOR NONWOVENS – PART 4: DETERMINATION OF TEAR RESISTANCE
TEXTILES – TEST METHODS FOR NONWOVENS – PART 3: DETERMINATION OF TENSILE STRENGTH AND ELONGATION
PLASTICS – FILM AND SHEETING – DETERMINATION OF THE COEFFICEINTS OF FRICTION
FLEXIBLE CELLULAR POLYMERIC MATERIALS – DETERMINATION OF TEAR STRENGTH
RUBBER- OR PLASTICS-COATED FABRICS – DETERMINATION OF TEAR RESISTANCE – PART 1: CONSTANT RATE OF TEAR METHODS
ADHESIVES – DETERMINATION OF TENSILE LAP-SHEAR STRENGTH OF RIGID-TO-RIGID BONDED ASSEMBLIES
TEXTILES – YARNS FROM PACKAGES – DETERMINATION OF SINGLE-END BREAKING FORCE AND ELONGATION AT BREAK
RIGID CELLULAR PLASTICS – DETERMINATION OF TENSILE PROPERTIES
FLEXIBLE CELLULAR POLYMERIC MATERIALS – DETERMINATION OF TENSILE STRENGTH AND ELONGATION AT BREAK
RUBBER OR PLASTIC COATED FABRICS – DETERMINATION OF TENSILE STRENGTH AND ELONGATION AT BREAK
RIGID CELLULAR PLASTICS – DETERMINATION OF COMPRESSION PROPERTIES
RUBBER, VULCANIZED OR THERMOPLASTIC – DETERMINATION OF ADHESION TO A RIGID SUBSTRATE – 90º PEEL METHOD
PLASTICS – DETERMINATION OF COMPRESSIVE PROPERTIES
PLASTICS – DETERMINATION OF TENSILE PROPERTIES – PART 3: TEST CONDITIONS FOR FILMS AND SHEETS
PLASTICS – DETERMINATION OF FLEXURAL PROPERTIES
RUBBER, VULCANIZED OR THERMOPLASTIC – DETERMINATION OF TENSILE STRESS - STRAIN PROPERTIES
RUBBER, VULCANIZED OR THERMOPLASTIC – DETERMINATION OF ADHESION TO TEXTILE FABRIC
RUBBER, VULCANIZED OR THERMOPLASTIC – DETERMINATION OF TEAR STRENGTH – PART 1: TROUSER, ANGLE AND CRESCENT TEST PIECES
RUBBER- OR PLASTICS-COATED FABRICS – DETERMINATION OF COATING ADHESION
PLASTICS – FILM AND SHEETING – DETERMINATION OF TEAR RESISTANCE – PART 1: TROUSER TEAR METHOD
PAPER AND BOARD – DETERMINATION OF TENSILE PROPERTIES – PART 2: CONSTANT RATE OF ELONGATION METHOD
This application study tests an aramid cord using Instron®’s standard pneumtaic cord and yarn grips and compares the results to those obtained with Instron’s unique pneumatic aramid cord and yard grips to determine which is more accurate and suitable.
Instron and Huxley Bertram Engineering have partnered to redevelop a key piece of equipment in the pharmaceutical development laboratory.
2820-061 Internal Bond Fixture for Wood
These are just some of the 100+ new features of Instron® Bluehill for Series IX users
These are just some of the 100+ new features of Instron® Bluehill for Merlin users
Technical article that explains the differences between a closed-loop hardness tester and a deadweight hardness tester; and provides a clear explanation of the advantages that closed-loop hardness testers hold over deadweight systems.
5500 シリーズの材料試験システムは、高性能ロードフレーム、高帯域幅 DSP (デジタル信号処理)方式のエレクトロニクスおよび Bluehill® 2 モジュール形式のアプリケーション ソフトウェアから構成されています。             
King portable Brinell hardness tester with 14 in. vertical capacity frame and 4 in. horizontal capacity. Test head and gage calibrated for test loads from 0-3000 kg. included.
Instron's non-contacting video extensometers' technology received US and European patents.
Wilson Instruments offers a line of semi- and fully-automatic systems for Knoop, Vickers and Rockwell hardness testing.
A letter to the customer: Instron's global calibration labs with accreditation to ISO 17025
This white paper is a comparative analysis detailing the advantages of load cells over pressure transducers.
モデル 3345 プラスチック試験パッケージは、プラスチック材料の引張および曲げ試験用の機械的試験システムです。最も汎用的な構成となっており、すぐに試験が始められます。このパッケージを品質管理やコンポーネント試験に活用すれば、お客様の顧客が期待する高い基準を満たす製品づくりを実現します。
モデル 3345 ゴム試験パッケージは、エラストマーの引張および引裂き試験用の機械的試験システムです。最も汎用的な構成となっており、すぐに試験が始められます。資材の受け入れ検査からコンポーネントの試験にも活用でき、お客様の顧客が期待する高度な基準を満たす製品づくりを実現します。
The partnership introduces a new testing system designed to measure and record radial stiffness and hoop strength of interventional medical devices.
High-temperature pneumatic action grips which provide a convenient method for clamping delicate films, polymers and woven fabric within a temperature controlled environment.
This issue includes an article on recycling plastics, as well as selecting jaw faces based on the hardness of your specimen. The Q&A is on the difference between load and stress.
SATEC Partner software is developed using professional standards described in this document. Software verification letter.
Instron continues its partnership with McLaren Technology Centre by providing the Formula One team with state of the art vehicle testing equipment.
Questions to ask when you need a calibration provider
Honda and Instron announce team supplier agreement.
モデル 3382 金属試験パッケージは、金属試験のための汎用的な構成の材料試験システムで、お客様の製品評価にすぐにお使いいただけます。インストロンが提供する信頼性と精度により、お客様は必要な結果と確信が得られ、顧客の期待に応えることができます。
Impact testing of automotive components to establish energy absorption characteristics.
Instron's ElectroPuls testing systems are ideal for a wide range of biomedical testing requirements.
The 2810-400 flexure fixture allows a variety of flexural tests to be performed, including determination of flexural modulus,flexural strength and flexural yield strength. Easy-to-install, the three-point fixture can be modified with an optional conversion kit to provide a four-point bending conversion
Instron's new SF1390 Series spring testing systems are ideal for spring manufacturers and end-users.
Instron's newest version of Bluehill Software is compatible with all 3300 Series systems.
Testing of Adhesives per ISO 11343 on Dynatup Impact System
The Instron® model XL (long travel) extensometer is a precise device for measuring strain in highly extensible materials such as elastomers, semi-rigid plastics and films.
インストロン3300シリーズ試験機で使用できるタッチパネル式コントローラです。生産性や使いやすさが最優先されるような品質管理アプリケーションなどに最適です。
Advanced Testing Systems for Spring Applications.
This document describes using Dynatup Impact system to test eye glass lenses or according to government impact resistence speficiations.
Instron introduces the ETMT 8800, a multifunctional testing system designed to test metals and other conductive materials.
Instron releases its 3rd Edition Accessories Catalog. This popular 450+ page catalog details a broad range of accessories to enhance materials testing systems.
The model 3342 start package is a state-of-the-art mechanical testing instrument that includes and all components necessary to start testing right away.
The ETMT 8800 Electrothermal Mechanical Testing System is based on the Instron advanced 8800 digital controller and Microtester test frame. The system developed by Instron is with unrivalled thermomechanical capabilities, available in an affordable benchtop package.
The Hand-Operated Marker (HOM) allows for marks to be placed on a specimen with consistent size, color density and spacing. Inks will stretch along with the specimen, unlike traditional stick-on paper dots that may move as the material is being strained, which can introduce error.
Webinar will cover what to do with your Impulse Data after you have collected it. Topics covered will include using the data explorer; use of data analysis options & tools; creation of user calculations and Impulse Systems Options.
Instron Limited's UKAS ISO17025 Calibration Laboratory Certificate
プライバシー ポリシー
2820-008 Tension Grips - Perpendicular to Grain Meets ASTM D 143 10 kN(1000 kgf, 2250 lbf) force capacity Designed for 50 mm x 50 mm x 62 mm (2 in x 2 in x 2.5 in) specimens
Instron's compression-only testing system is used to test large springs on locomotives.
Catalog Number 2712-002 Rated capacity 250 N (25 kgf, 50 lbf)
グリップ、治具、ロードセル、ソフトウェア、恒温槽など、インストロンはさまざまなアプリケーション要求に適合するアクセサリーを取り揃えております。
Instron® Extra services revolve around your long term needs - Web Support, Telephone Support, On-Site Support, Software Support, Calibration Services, Training and Consultancy and Life Cycle Management.
Catalog number 2713-001 Rated capacity 1 kN (100 kgf, 225 lbf) Ideal for testing elastomers, flexible plastics and thin films. Temperature range: -20 °C to 150 °C (-4 °F to 300 °F)
Researchers at the University of Cambridge, UK, study the biomechanics of the carotid artery.
Westmoreland Mechanical Testing and Research, Ltd purchases 10 Instron servohydraulic test frames.
Accessories e-newsletter containing articles on non-contact extensometry and plastic strain.
Accessory e-newsletter containing articles on wood fixtures and part one of gripping solutions and care
Accessories e-newsletter containing articles on the Bio bath and part two of gripping solutions and care.
Accessory e-newsletter containing articles on Versa channel and part three gripping solutions and care.
The SF1390 series features a robust floor standing design with two lead screws and two precision guide columns for maximum stiffness. A servo drive controls the frame’s loading crosshead for fully automatic load testing. The system is controlled by Instron’s Partner™ spring testing software. Load and height data are collected on-the-fly during the nonstop test stroke. Load versus height graphs and test results are clearly displayed on the computer screen. Results are stored in a database and can be accessed via a network connection or printed in a customizable report.
Instron's customized 9000HLX Universal Testing System is designed to test materials for the San Francisco-Oakland Bay Bridge East Span Seismic Safety Project.
This issue includes articles on fracture devices and Honda Formula 1. The Q&A is on choosing the right extensometer when determining a yeild stress.
The Biopuls multi-axial spine testing system is a powerful and flexible tool for investigating spine kinematics. The system allows full simulation of physiological spine motions and loads.
The manual wedge action grip is designed for easy specimen loading, alignment and positioning. After initial face to specimen contact, gripping force will increase as the testing load increases. Virtually no preload is seen during specimen clamping due to Instron's design of moving grip bodies. This makes them particularly suitable for testing high strength materials, such as metals and composites, ensuring that specimen slippage is eliminated.
Instron’s Model EXL (Extra Long Travel) Extensometer is a precise device for measuring strain in highly extensible materials such as elastomers, semi-rigid plastics and films. Designed for use in ectromechanical testing instuments the EXL can be used to measure the specimen’s elongation up to 30 in or 750 mm.
ElectroPulsTM E3000試験機は最新鋭のエレクトロダイナミック試験システムです。オイルフリーのリニアモーターで駆動するこのシステムは、±3000Nの動的荷重容量と±2100Nの静的荷重容量を備えています。
ElectroPulsTM E1000 試験機は最新鋭のエレクトロダイナミック試験システムです。オイルフリーのリニアモーターで駆動するこのシステムは、±1000Nの動的荷重容量と±710Nの静的荷重容量を備えています。また、E1000は縦置きだけでなく、オプションで水平設置も可能です。
ElectroPulsTMタワーは ElectroPulsシステム用の最新鋭のデジタルコントローラです。
This special issue of TechNotes is focused on gripping tips, along with a 20% jaw face discount offer.
Instron introduces a coil spring load center testing system designed specifically for the automotive industry.
8870シリーズは、ねじり入力にも対応する高精度な油圧サーボ疲労試験機です。卓上に設置可能なコンパクトな設計になっており、広範囲におよぶ静的および動的試験の高度なニーズに応えられるように開発されています。
Pamphlet of 20 pages that explains seven tips for tests of materials.
Brochure focused on impact testing applications of components in the aerospace, automotive, construction, consumer, electronics, industrial, medical, and sporting goods industries.
This issue includes articles on Skyline High School and high strain rate testing. The Q&A is on negative load value.
Dynatup offers the 8200 drop weight impact test machine to meet the need for a small mass, drop weight impact test machine with a range of adjustable energies and velocities. The 8200 is ideal for low-energy testing of thin section or brittle plastics, composites, ceramics, films and metals. The machine's wide range of test configurations allows for testing of both specimens and actual components.
Proper calibration of your test system is the first step in ensuring that your lab is producing high quality data and valid results. Current issues related to calibration in materials testing labs include changes to national and international standards, accreditation to ISO 17025, and uncertainty of measurement. We will discuss recent changes to force, strain, and hardness standards, the release of a new ASTM standard for displacement calibration, and other potential new standards. Since not everyone is really sure what accreditation is all about, we will give an introductory review of why accreditation has value, who performs the accreditation, and how ILAC fits into the picture. ISO 17025 requires uncertainty of measurement analyses from testing laboratories. We will give an example of how the uncertainty of calibration can affect the total uncertainty of the test results.
Two-page brochure for Wilson Instruments Rockwell 2000 Series hardness testers. The Rockwell 2000 features a unique, electronic closed-loop control system for superior accuracy and repeatability. Available in 3 sizes and in regular, superficial and twin scales.
Impact testing application note for pharmaceutical tablets.
荷重容量最大600kNまで対応可能な油圧式万能試験機
This issue includes articles on spine testing and Nanocomposites, Inc. The Q&A is on elastic modulus values.
This issue includes articles on Instron's deadweight stack and Tissue Regeneration, Inc. The Q&A is on hardness test blocks.
Short, descriptive flyer of Wilson Instruments' ATA computerized autotesting systems - software-based measurement packages designed to increase productivity, accuracy and efficiency through automating the measurement and/or the stage navigation process.
Catalog Numbers 2711-002, 2711-003, 2711-004, 2711-007 Rated capacity 0.75 N (0.075 kgf, 0.165 lbf) Small single polymer fibers
Catalog number 2712-012 Rated capacity 10 kN (1,000 kgf, 2,250 lbf) Specimens from delicate films to polymers and woven fabrics.
performing in-plane compressive properties of polymer matrix composite material reinforced by high modulus fibers, procedure A and B. IITRI design for method B - Celanese design for method A Catalog Number 2505-001/ 002/ 020
Performs compressive strength tests, generally on quasi-isotropic composite material, as well as multidirectional polymer matrix composite laminates reinforced with high modulus fibers. Catalog Number 2505-027
The recently issued ASTM standard, F2516-05: Standard Test Method for Tension Testing of Nickel-Titanium Superelastic Materials, suggests that strain measurement for nitinol specimens can be determined by machine crosshead motion, a clip-on extensometer or a video extensometer. The purpose of this study was to compare the three different methods for testing nitinol tubing. Stress-strain results reveal that the video extensometer and the clip-on extensometer provide for comparable results. However, the non-contacting video extensometer may eliminate slipping and premature failure that are common sources of error with the clip-on extensometer.
Items to consider when changing from steel to carbide balls when complying with the new ASTM E 18 standard.
Tables define the difference in Rockwell hardness levels, when changing from steel to carbide balls. Data is given for several different Rockwell ball scales.
Catalog Numbers 2620-613/614/615/619/620/621 Available in gauge lengths of 12.5 mm, 25 mm or 50 mm (0.5 in, 1 in, 2 in)
Catalog Numbers 2640-007/ 008/ 001/ 003 pod_2640-007-008-001-003_rev3_0704
The flexure fixture allows a variety of flexural tests to be performed, including determination of flexural modulus, flexural strength and flexural yield strength. Easy-to-install, the three-point fixture can be modified with an optional conversion kit to provide a four-point bending conversion
Instron®’s policy is to conduct business in a responsible manner within the guidelines set out by the US, UK and German export control regulations and laws...
“A picture is worth a thousand words…a video is the final word!” Bluehill 2 Video Capture Module allows you to record and replay the actual test event associated a test curve in order to examine specific regions and points of interest, e.g. modulus, yield, peak and break, for materials and components that produce distinct test curves.
インストロンは、万能試験システムである新しい KN モデルを提案します。永年に渡る経験から、インストロンは、静的油圧技術を最高レベルに保ち、この新しい SATEC シリーズに、設計の柔軟性、最新の外観、高性能なエレクトロニクス、最先端のソフトウェアを導入しています。
As the world's leading supplier of material testing systems, Instron offers a wide range of texture testing solutions for the food industry
Accurate and repeatable results are the goal for any good testing program. Unique characteristics of springs, most notably coil compression springs, can cause errors that make this goal difficult to achieve. You will learn about factors such as extraneous forces, frame deflection and others that cause errors, as well as how to minimize their affects on your load testing results. In addition, you will learn about some advanced analysis techniques some of our customers are using to differentiate their products in the market. These techniques are made possible by analyzing the entire spring characteristic curve (load vs. height) to determine multi-rate spring transition points (knees), spring non-linearity and others.
Webinar on "Why Your Results Don't Look Right -Hidden Errors in Your Data" presented by Christopher Scott on April 5, 2006.
This document describes a 3300 Series instrument with Touchpanl controller and accessories for Quality Control applications.
The Instron Force Standards Laboratory offers calibration services that allow you to comply with ISO376 and ASTM E 74 requirements for calibration of secondary standards and working standards.
Force calibration services for materials testing instruments
A 2-page flyer illustrating Impact testing solutions for standards and components in the plastics and film industry.
Simulates knee joint loading and motion.
With increasing recognition that testing systems must be properly aligned for the best test results, Instron's alignment calibration service is now offered for most types of testing machines. A comprehensive characterization of the load frame alignment is provided per ASTM E 1012 using a strain gaged specimen. The brochure lists standards that require alignment and a sample calibration report.
T-slot tables provide an extended work area primarily intended for clamping components or structures for performing tensile, compression or flexural tests. The T-slot table is mounted directly on to the base platen of the machine, and components/ structures can then be secured in position on the table using the various clamping tools supplied.
T-slot tables provide an extended work area primarily intended for clamping components or structures for performing tensile, compression or flexural tests. The T-slot table is mounted directly on to the base platen of the machine, and components / structures can then be secured in position on the table using the various clamping tools supplied.
Two-page overview of Wilson Instruments Hardness products; such as Rockwell hardness testers, Knoop and Vickers testers, portable testers, accessories and calibration.
Instron Dynatup releases its Impact Applications Brochure, which focuses on component-level testing.
Instron now offers a subscriber-only e-newsletter, covering topics on a wide range of accessories for materials testing.
マイクロエレクトロニクス、バイオメディカルをはじめ、重要な極小部品を使用するアプリケーションに理想的な試験機です。マイクロテスターは、高剛性のロードフレームとナノレベルの高い位置測定精度を可能にする精密駆動システムで構成されており、比較的単純な静的試験から、複雑な入力が要求される動的なサイクル試験まで、引張、圧縮、曲げ、せん断など様々な試験が可能です。マイクロエレクトロニクス分野では、ダイせん断、フィルム接着強度、リード引張など幅広く利用されています。ASTM、EN、ISO、JISなどの規格に準じた材料試験や製品試験、さらにお客様独自の試験パラメータによる試験も可能です。また、環境槽を組合わせ、温度などの環境試験にも対応できます。
Catalog number 2713-006 Rated capacity 100 N (10 kgf, 22 lbf) Ideal for natural rubber latex, elastomers, paper and polymer films
5590-HVLシリーズは高容量の万能材料試験システムです。高性能のロードフレームおよび最先端のデジタル信号処理エレクトロニクス(高性能DSP)で構成されています。 <カタログNO:WB1146J> 2002年5月版         
Accessories e-newsletter containg articles on screw action grips and compliance.
User manual for Wilson Instruments Rockwell models TT & TY new style. New style TT & TY hardness testers are characterized by minor load setting at front of tester near indenter.
Simple application note about the In-Spec in use with a stereo microscope, for observing the sample during testing.
Cyclic tests were run on conveyor belt material in accordance with ISO 9856.
The purpose of this test was to determine a method for measuring the bond strength of solder ball contacts to IC packages. Tension tests were performed on two types of packages, one with 508 contacts and the other with 52 contacts.
The purpose of this test was to accurately measure the force required to break a crimp joint between a 32 mm long metal pin and the surrounding metal body in compression.
The purpose of these tests was to measure the modulus of rupture (maximum stress) and the flexural modulus of two types of small graphite/epoxy specimens using a four-point flex fixture.
Tensile, buckle and recovery tests were run on Avistrap PW100 cord stapping. Two 1¼ inch wide samples were tested for tensile and buckle tensile properties. One sample was tested for recovery properties.
The purpose of the test was to demonstrate the Instron 5542 for testing small disks in compression. Tests were run on wet and dry disks using both the crosshead and Linear Variable Differential Transducer (LVDT) for measuring displacement.
A tack test is a common method for evaluating the adhesiveness of a material and to compare adhesiveness between materials.
The purpose of this test was to determine the force required to break a pressed connection between four tubes and an aluminum part.
Compression test of keypads using a model 5569 series was performed to simulate loads required in typing.
Cyclic compression tests were performed on small circular springs and circular gland seals using the TestProfiler software.
User manual for Wilson Instruments Rockwell hardness testers models JR & JS.
User manual for Wilson Instruments Rockwell models OUR and OUS hardness testers.
User Manual Wilson Instruments Rockwell models TT & TY hardness testers (old style). Old style characterized by minor load housing at the top rear of the tester.
User manual Wilson Instruments Model Tukon 300 user manual.
One page flyer featuring Instron Dynatup 9250 impact test instrument configured for plastic conduit and pipe testing per UL 651 and ASTM D2444
Miniature 90° Peel Fixture Cat. no. 2820-034
Steel welded wire fabric, made from either cold-worked deformed wire or a combination of deformed and non-deformed wires, is often used in concrete reinforcement. In addition to the tensile strength and bend strength of the welds that support the fabric, the shear strength of the longitudinal and transverse wires is also important to characterize.
The manufacturer of a cleaning solution that is packaged and delivered for use in the food industry has received customer complaints that the solution is leaking at some point during shipment. It is possible that the adhesive or the process used to seal the package is insufficient for preventing leakage of the solution over time. A comparison of the strength of the packaging material compared to the strength of the seal through a series of peel tests may provide insight into the problem.
The Advanced Video Extensometer (AVE) has the ability to measure axial and transverse strain without contacting the specimen. Such non-contacting strain measurement is advantageous for testing thin and delicate specimens. The purpose of this test was to evaluate the AVE as a tool for calculating Poisson's Ratio in strips of polymer membranes in accorance with ASTM D 882.
A manufacturer of conveyer belt material was experiencing problems when trying to test their product in tension. The conveyer belt samples either slipped out of the jaw faces due to the inherent lubricity of the material or the test resulted with a jaw break. Samples were sent in to determine if there was a configuration available to resolve this issue.
Sheet metal tensile testing applications require the use of an extensometer to comply with relevant ASTM and ISO testing standards accuracy requirements. In some cases, the thickness of the specimens may be too thin for use with a traditional clip-on extensometer. Developments in the technology of extensometry offer metals testing customers other options, such as the Instron® Advanced Video Extensometer (AVE) for testing aluminum specimens in tension.
A manufacturer of consumer breath freshening strips uses the In-SpecTM 2200 electromechanical system to determine the tensile strength and elongation ofvtheir products. These results provide quality assurance in manufacturing and production, ensuring customer satisfaction.
Sheet metal testing applications require calculations such as yield strength, yield point elongation, ultimate tensile strength, plastic strain ratio ('r' value)and the strain hardening exponent ('n' value). These calculations place a high physical demand on traditional contacting extensometers. The purpose of this testing was to evaluate the Advanced Video Extensometer (AVE) for performing non-contacting strain measurement on steel specimens.
A manufacturer of ammunition pellets used in a variety of firearms uses an Instron® electromechanical test system to evaluate the compressive strength of the pellets and the type of deformation they exhibit under load. Further, the shelf life of these pellets must also be quantified in order to guarantee performance over time.
Characterization of the mechanical properties of materials used in space flight is at the forefront of research and development activities for NASA. One such test required the calculation of Poisson's Ratio, a measure of a material's compressibility, on foam material used in the construction of space shuttles in accordance with ASTM D 1623, "Standard test method for tensile and tensile adhesion properties of rigid cellular materials".
Evaluation of a pillow's comfort or firmness has historically relied on surveys completed by employees or customers' feedback. In an attempt to quantify these measures of comfort, one pillow manufacturer delivered several pillow specimens to Instron® to explore testing configurations that could produce repeatable data to correlate with that generated from the customer and employee surveys.
A manufacturer of composite materials uses an Instron® electromechanical testing system and 3-point bend fixture to determine the flexural modulus, flexural strength and flexural strain of their composite bars. The test was conducted according to the ASTM D 790, "Standard Test Method for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials".
There are two common challenges in conducting high-speed, low-force testing. The first challenge is overcoming the inertial force resulting from acceleration of the upper grip and the crosshead. The second challenge is to reduce the amplitude of the resonant frequency resulting from the combination of a high rate of crosshead extension and the grips and load cell used. The purpose of this testing was to isolate these issues and provide a solution for minimizing their effects.
A manufacturer of copy paper needs to investigate the cause of copy machine failure as a result of frequent paper jams. A Coefficient of Friction (COF) test was recommended to measure the static and kinetic coefficients of friction between two sheets of paper. Because no specific testing standard outlines a method for this type of material, ASTM D 1894 "Standard Test Method for Static and Kinetic Coefficient of Friction of Plastic Film and Sheeting" was followed.
Four different fabric samples were tested using a ball burst fixture in accordance with ASTM D 6797 to measure the burst strength of each and compare values between samples. The test was used to investigate the effect of different chemical treatments on the mechanical properties of the fabric.
Tensile testing of thin plastic sheeting in accordance with ASTM D 882 is a common testing requirement for many Instron customers. Gripping of these delicate specimens is the prevalent challenge in most tests. The gripping technique must prevent slipping of the material at high loads but not tear into the material and cause premature specimen failure.
A manufacturer of coated fabrics is interested in evaluating the effect of a particular coating on the flexural properties of fabric material. Four different coated fabric samples were delivered to the Instron® demonstration laboratory for evaluation.All testing was conducted in accordance with ASTM D 790.
Tensile testing on textile fabrics used in the automotive industry using a grab test in accordance with ASTM D 5034.
Recent studies have shown a relationship between mechanical testing of food, called Texture Profile Analysis (TPA), and the texture of food. TPA was performed to differentiate between three varieties of tofu.
Instron offers its exclusive Web Support Agreement (WSA) to customers in Europe and Asia.
Instron offers an improved line for wood and adhesive testing.
Instron's multi-axial spine testing system used by the University of Minnesota to achieve 6-degrees of freedom.
Webinar on Impact Test Machine Parameters presented by Stephanie Williams on November 30, 2005. Webinar covered potential common configuration errors that could cause errors in your data.
Webinar on VersaChannel was presented by Bruce Boswell on January 11, 2006. This webinar describes the hardware and software components that make up the VersaChannel option. Learn how to install and connect typical extra channels to the system. We discuss software configurations, specific channel settings, and the calibration of different configurations. We demonstrate using the extra channels in Bluehill live displays, calculations, and graphs.
Webinar on Tips and Techniques on using the Video Extensometer presented by Sean McNeill and Richard McManuis on February 7, 2004.
Webinar on Portable Testing presented by Lorenzo Majno on May 26, 2005 The In-Spec Series of Portable Testers is designed to allow users to take the tester with them, to test things outside the lab, and to make field measurements. Applications include medical devices, agriculture, food, and light duty quality control testing.
Webinar on Hidden Errors in Your Data presented by John Reskusich and Larry Frost on June 26, 2003.
Webinar on "Why Your Results Don't Look Right - Hidden Errors in Y our Data" presented by Christopher Scott on October 19, 2005.
Webinar on Bluehill Software presented by Jim Ritchey and Frank Lio on July 15, 2004, October 27, 2004 and December 8, 2004.
Webinar on Advances in Video Extensometry(AVE) presented by John Reskusich and Bruce Boswell on January 26, 2005. This webinar provides an overview to the new technologies applied to the most recent Instron video extensometer - the AVE (Advanced Video Extensometer).
Overview of webinar conducted that provides in-depth description and explanation of the change to ASTM E 18 regarding the use of carbide balls for hardness testing.
As the world's leading manufacturer of materials testing equipment, Instron is the premium choice when it's time to upgrade. Our Extend packages have been added to over 5000 systems worldwide.
Dynatup Impulse V3.0 release flyer with features and screen shots.
This data sheet describes the Serial Port Option for the TouchPanel controller. The serial port option allows test results to be transferred directly to an SPC computer.
Recent studies have shown a relationship between mechanical testing of food, called texture profile analysis (TPA), and the texture of food. A compression method and indentation method were used to differentiate between three varieties of tofu.
Texture testing for a variety of foods, using application specific fixtures such as the Kramer Shear Cell and the Back Extrusion Cell.
Test solutions for large-scale structures, materials and components used in construction. Encompassing a broad range of complete testing solutions, including configured machines and component based rig systems.
Guideline for the installation of a hydraulic ringmain, including information on pipes, valves, connections, and shutoffs.
衝撃試験アプリケーション用のデータ収集/解析ソフトウェアと高性能エレクトロニクス。 <カタログNo. WB1150J> 2002年6月版
Shock Absorber Test Machines Type MSP for Damper Testing. They are conceived to analyse and assess accurately and reliably the material properties and characteristic of all kind of damper types (e.g. single/ twin-tube shock absorbers, seat and steering dampers, metallic impactors etc.)
Realise the potential of your operator personnel and investment in Instron® equipment through comprehensive ‘hands-on’ interactive instruction.
Realise the potential of your operator personnel and investment in Instron® equipment through comprehensive ‘hands-on’ interactive instruction.
Realise the potential of your operator personnel and investment in Instron® equipment through comprehensive ‘hands-on’ interactive instruction.
Realise the potential of your operator personnel and investment in Instron® equipment through comprehensive ‘hands-on’ interactive instruction.
Realise the potential of your operator personnel and investment in Instron® equipment through comprehensive ‘hands-on’ interactive instruction.
Realise the potential of your operator personnel and investment in Instron® equipment through comprehensive ‘hands-on’ interactive instruction.
Realise the potential of your operator personnel and investment in Instron® equipment through comprehensive ‘hands-on’ interactive instruction.
Realise the potential of your operator personnel and investment in Instron® equipment through comprehensive ‘hands-on’ interactive instruction.
Shore® Instruments offers a unique system of o-ring fixtures designed with interchangeable inserts.
Comprehensive 40-page brochure encompasses the full range of Hardness testers from Wilson Instruments. Includes Rockwell, Knoop/Vickers, Brinell, and automated systems.
2820-060 Shear Test Fixture for Wood
This notice only relates to “Shoulder End Holder” Inserts that were purchased prior to May 2004 and that have been used repeatedly at testing forces above 30,000 lbs (133 kN). The insert is rated for 60,000 lbs (267 kN). Instron has determined that a fatigue failure of the insert may result from repeated test’s at forces above approximately 50% of the insert’s rated capacity. Use below 50% of capacity is not expected to lead to failure. A design change was made to the thread of this insert in April 2004 that has addressed this issue.
Cat. number 2710-200
Instron presents award for a novel interface system for prosthetic limbs to the University of Surrey, UK.
Instron introduces its new 5500 Series Accessories designed for the biomedical testing industry.
Advanced test systems to be deployed for testing spine implant devices.
Technical publication describing the basic fundamentals of Rockwell Hardness testing.
Instron Calibration Laboratory is accredited to work with ISO 7500-1 and 7500-2 for the verification of testing machines used for uniaxial creep testing in tension in accordance with ISO 204.
Motorized testers with a robust ‘C’-frame design and single preloaded ballscrew for spring testing up to 2 kN (450 lbf).
Catalog number 2741-081, 2741-082, 2741-083, 2741-084
2742 Series (2742-301)
2742 Series (2742-504)
Catalog Number 3118-304/3118-313
Catalog Number 2736-015
Catalog Number 2732-101
Catalog Number 2718-624
Catalog Number 2712-212/213/214
Catalog Number 2742-404
Catalog Number 2732-212/2732-213/2732-214
Catalog Number 2718-628
Catalog Number 2718-621
Catalog Number 2712-111
Describes the test process used to ensure that Bluehill calculations are valid.
Bluehill 2 software is developed using professional standards that are included in this document.
Instron calibration of your impact tester gives you a statement of how well your system is performing. Instron impact calibrations are carried out againast the appropriate international standard.
Hydraulic Wedge Action Grips - 100 kN (Cat.No. 2743-401)
Shore Instruments offers the S1 Digital Durometer, ideally suited for hardness testing of rubber and plastic.
At Instron, we are experts in upgrading material test systems. Through our EXTEND packages, we upgrade Instron and non-Instron load frames with the latest digital electronics and application software.
2741 Series Mechanical Buttonhead Grips Catalog Number 2741-081, 2741-082, 2741-083, 2741-084
+800 °C Reverse Stress Pullrods Catalog number 3117-050
2742 Series ±250 kN (56 kip) Fatigue-Rated Hydraulic Modular Grips Catalog number 2742-504
Series 2742 ±30 kN (6.8 kip) Fatigue-Rated Hydraulic Wedge Grips Catalog number 2742-301
±25 kN/100 Nm (5.6 kip/0.6 kip-in) Axial/Torsional Hydraulic Grips catalog number 8260C
+600 °C and +1000 °C Tension Only Pullrods Catalog numbers 3117-020, 3117-021
2860 Series Stud Pull Fixture catalog number 2860-300
2860 Series PCB Clamping Stage catalog number 2860-200
2860 Series X-Y and Theta-X-Y Manual Translation Stage catalog number 2860-100
90° Angle Peel Fixture catalog number 2820-035
2743 Series ±25 kN/100 Nm (5.6 kip/0.6 kip-in) Axial/Torsional Hydraulic Grips Catalog number 2743-100
+600 °C (+1112 °F) Reverse Stress Pullrods Catalog number 3117-030
Catalog number 3117-022
Catalog Number 2860-001
2718 Series Pneumatic Hydraulic Power Pack Catalog number 2718-420
Pneumatic action grips allows rapid, easy loading of specimens from delicate films to polymers and woven fabrics. This provides a very simple and efficient method for holding test specimens easily and quickly.
Pneumatic action grips allows rapid, easy loading of specimens from delicate films to polymers and woven fabrics. This provides a very simple and efficient method for holding test specimens easily and quickly.
2718-600 Series Hydraulic Grips Catalog number 2718-622
2850 Series T-Slot Tables Cat. no. 2850-033
Catalog Number 2820-026. Precisely measures adhesive strength of tapes, laminated release coatings, paper and plastic films. Maintains constant 90° peel angle for accurate measurements.
Application Report highlights features of 1500 KN Static Hydraulic Test Machine for rebar testing.
Displacement calibration services
Speed calibration services
Speed calibration services
Force calibration services for materials testing instruments
Catalog number 2810-200 Rated capacity 250 kN (25000 kgf, 56250 lbf) 3-point flexure fixture with an optional conversion kit for 4-point loading
Catalog number 2810-181
This document describes the features, benefits and specifications of the S1 Durometer
The Ottawa texture cell is used primarily for determining texture properties of fruits and vegetables. The upper part or plunger of the Ottawa cell is attached to the load cell. The lower part consists of an extrusion box with interchangeable inserts. Catalog Number: 2830-040
The Kramer shear cell is a multi-bladed fixture designed to produce shear stresses in a specimen that relates to firmness. The Kramer cell is used mostly for fruits and vegetables but can also be used to evaluate meat cubes and nuggets. Catalog Number 2830-018
Catalog Numbers 2810-097*/ 130/ 191 Two capacities: 10 kN (1,000 kgf, 2,250 lbf) and 100 kN (10,000 kgf, 22,500 lbf) Meets the ASTM D 3574 and ASTM D 5672 standards* Meets the EN ISO 2439:2000 standard
The Warner-Bratzler shear fixture includes a 1 mm (0.04 in) thick nickel plated steel blade with a vee-shaped notch. The 60° angle notch has a 0.5 mm (0.20 in) radius at the cutting edges. The blade is precision ground flat to reduce friction as it passes through the blade guides.
Catalog number 2830-011 is designed for determining bread firmness. This 10 cm2 (1.5 in2) aluminum anvil meets the requirements specified by the American Association of Cereal Chemists. Catalog number 2830-009 is a stainless steel anvil designed for general deformation and fracture testing.
Catalog number 2830-008 is a set of four stainless steel plates for use with puncture probes or compression anvils. The set consists of one flat plate and three plates with various shaped holes. The holes are useful when performing tests on round shapes like fruits that tend to roll on a flat surface. The holes also assists in centering the specimen relative to a puncture probe or compression anvil. These plates are designed to be used with the support frame and drip tray.
Flat-end puncture probes produce a shear stress in the specimen. The force required to cause shearing as the probe penetrates the specimen relates to texture properties such as firmness and hardness. Catalog Number: 2830-006, 2830-036, 2830-005, 2830-015
Catalog Number 2820-020 and S1-11237. Precisely measures the relative peel resistance of high strength adhesive bonds between a rigid adherend and a flexible adherend.
The back extrusion cell consists of a plunger that connects to the load cell and a cylindrical cup that holds the test specimen. The cup is mounted in a drip tray that contains any specimen overflow that may occur during the testing. The drip tray mounting plate has four pins that accurately locate the cup concentrically to the plunger. This design simplifies removal of the cup for cleaning and ensures a consistent 4 mm (0.16 in) gap around the plunger.
Waiting on desc.
Waiting on desc.
The 2820-019 climbing drum peel test fixture is designed to measure the bond strength of adhesive bonds in honeycomb materials with rigid backing.
The 2820-015 climbing drum peel test fixture is designed to measure the bond strength of adhesive bonds in honeycomb materials with flexible backing.
Catalog number 2810-250 Rated capacity 500 kN (50000 kgf, 112500 lbf) 3-point flexure fixture with an optional conversion kit for 4-point loading
2810 Series Flexure Fixture Catalog number 2810-206
2850 Series T-slot tables catalog no. 2850-201.
The AsphaltPro Direct Tension Test System (DTT) is a complete solution for determining the failure properties of asphalt binder at low temperatures to meet the current Superpave Performance-Graded Binder Specification (AASHTO M320).
Instron® offers a fully integrated indirect tensile testing system which is designed for determining the creep compliance and tensile strength of hot mix asphalt (HMA) in accordance with AASHTO specification T 322. Tensile creep and tensile strength are required in SUPERPAVE levels 2 and 3 designs to determine the master relaxation modulus curve and fracture parameters. This information is used to calculate the fatigue performance and thermal cracking of HMA.
Instron®'s latest addition to its family of asphalt test systems is the new toughness and tenacity asphalt tester. We have leveraged our expertise in direct tension testing to provide a system designed specifically for measuring the toughness and tenacity of bituminous materials.
FastTrack 8800油圧サーボ試験システムは、最新鋭のコントローラとソフトウェアで構成されています。高度な制御機能とデータ処理機能を備え、低サイクル疲労試験から高速疲労試験、熱機械疲労(TMF)試験や生体適合材料試験など、様々な疲労試験に対応しております。
Wilson Instruments introduces its 400 Series of Knoop/Vickers Testers ideal for metals, ceramics and other non-metallic materials.
Instron offers its Web Support Agreement (WSA) for Bluehill 2 software users. WSA members can now access their custom Web site directly from Bluehill 2 software.
Instron introduces a new Hydraulic Testing System with Single-Side Acting Hydraulic Grips - allows for accurate and reliable testing.
Instron releases its 2nd edition Accessories Catalog. This popular 480 page catalog details a broad range of accessories to enhance materials testing systems.
標準ビデオ伸び計(SVE)は、高解像度デジタルカメラとLEDライトを使用し、非接触でのひずみ測定を実現しています。高度なリアルタイム画像処理技術により、試験片の正確な軸方向および横ひずみ測定が可能です。
Piston-compressed air and oil dampers are used in many applications, such as on automobile doors and in engines. The testing challenge in this application is overcoming the inertia created by the test frame crosshead as it is compressed to the hold points.
This report summarizes the test configuration recommended for evaluating the forces required to eject fluid from a syringe. It is important that the material and design of both the syringe and the needle be tested, as both will have an effect on the overall forces required of the end-user. The challenge in testing these tubular specimens is to create a platform in which the syringe can be placed and remain stable while a compressive force is administered on the plunger from above to mimic normal use of the device.
Strain calibrations give you a statement of how well your system is performing, particularly when you use extensometry to determine strain measurements.
Kevlar and Spectra are high strength, polymeric fibers, with diverse applications. When testing both Spectra and Kevlar, precise measurement of ultimate elongation, maximum load, and ultimate strain are imperative in determining the mechanical properties. This report summarizes the test configuration used for such an application.
The strength of adhesive bonds depends greatly upon the conditions under which the bonding process is carried out and the testing for which is described in ASTM D 1002, Lap Shear Strength of Adhesively Bonded Metal Specimens. This report demonstrates the capabilities of the Instron test frame and software for testing in accorandance to this standard.
Upgrade Systems Extend Instron 4500 Series Universal Testing Systems pod_Extend4500_rev3_0705
Upgrade Systems Extend Instron 1100 Series Universal Testing Systems pod_EXTEND1100_REV3_0705
Extend Instron 6000 Series Universal Testing Systems extend6000 pod_EXTEND6000_REV3_0705
Upgrade Systems Extend Instron 1120 Series Universal Testing Systems pod_EXTEND1120_REV3_0705
Statement on the Environmental Impact of Instron Electromechanical Testing Machines. Instron electromechanical machines are designed to produce no adverse environmental impact during normal use as long as they are operated and serviced in accordance with their operating instructions.
Instron Australia is accredited to ISO17025 for performing Calibrations on Materials Testing Machines to AS2193 and AS1545
Describes the test process used to ensure that Bluehill calculations are valid.
Series IX (Version 7.XX and 8.XX) software is developed using professional standards described in this document. Software verification letter.
Dynatup Impulse software is developed using professional standards described in this document. Software verification letter.
Catalog Number: 2850-003. The single axis specimen measuring unit can be used in both manual and automated Instron testing systems. The unit includes probes tips, stand, foot-switch, RS-232 interface, and connecting cables.
2820-010 Compression Fixture - Perpendicular to Grain 25 kN(2500 kgf, 5625 lbf) force capacity Designed for 50 mm x 50 mm x 150 mm (2 in x 2 in x 6 in) specimens Meets BS 373 and ASTM D 143
2820-004 Hardness Test Fixture Meets BS 373, ASTM D 143 and ASTM D 1037 100 kN (10,000 kgf, 22,500 lbf) force capacity Designed for 50 mm x 50 mm x 150 mm (2 in x 2 in x 6 in) specimen sizes pod_2820_004a_0203
Bluehill software is developed using professional standards that are included in this document.
Instron were proud to sponsor the Symposium on Structural Durability in Darmstadt, Germany and present the Instron Award 2005 to Martin Küppers from the Fraunhofer Institute for Structural Durability LBF in Darmstadt.
The new Wilson Instruments Multi- Mount Clamping fixture is designed to support and clamp multiple mounted samples, and other typical Microindentation materials.
The North American Instron Calibration Lab is now ISO 17025 accredited (NVLAP Lab Code 200301-0) for on-site calibration of Speed, Displacement, Stroke, and Temperature.
Catalog Number 2820-012. This specially designed fixture allows accurate 3-point static bend testing to be performed on timber.
Strain calibrations give you a statement of how well your system is performing, particularly when you use extensometry to determine strain measurements.
2820-011 Tension Grips for Chipboard, Fibreboard etc - Perpendicular to Surface. The tensile strength of chipboard, fibreboard, hardboard etc. perpendicular to the surface requires the use of these specially designed grips.
Describes the ability of the In-Spec 2200 Mechanical Tester to perform tensile tests on plastic joints and medical tubing. The In-Spec is ideal for quality assurance testing and applications where bringing the tester to the specimen is advantageous.
2820-003 Cleavage Fixture for MONNIN specimens Meets BS 373 and ASTM D 143 10 kN(1000 kgf, 2250 lbf) force capacity Designed for 50 mm (2 in) x 76 mm (3 in) specimen cleavage area
2820-002 Shear Fixture - Parallel to Grain - guillotine type frame Meets BS 373 and ASTM D 905 100 kN (10,000 kgf, 22,500 lbf) force capacity Ideal for evaluating adhesive shear properties in bonded wood
Rated capacity 100 kN (10,000 kgf, 22,500 lbf) Temperature range: -73 °C to 315 °C (-100 °F to 600 °F)
Catalog Number 2810-182 3-point flexure fixture with an optional conversion kit for 4-point loading Rated capacity 100 kN (10,000 kgf, 22,500 lbf)
Hydropuls Crash Simulation System. Our servohydraulic Catapult works in a non-destructive way. The System is designed so that all applications currently available, e.g. Pitching, Sled-on-Sled Test, Side Impact Simultation etc. can be retrofitted at a later stage.
The software package RS MePar(Mechanical Parameters)is a Softwaremodule out of the RS LabSite Software Suit for determining the characteristics of components with visco-elastic properties.
These high force digital control servomechanical testing systems are a result of Instron’s continual effort to provide the best in high capacity universal testing frames.
Rated capacity 100 kN (10,000 kgf, 22,500 lbf) Temperature range: -73 °C to 315 °C (-100 °F to 600 °F)
Catalog number 2732-006 Rated capacity 100 N (10 kgf, 20 lbf) Temperature range: -70 °C to 315 °C (-100 °F to 600 °F)
Catalog number 2732-004 Rated capacity 1 kN (100 kgf, 225 lbf) Temperature range: -70 °C to 315 °C (-100 °F to 600 °F)
European Calibration Laboratory now includes Charpy Impact to EN 10045-2 and ASTM E 23
Instron Offers Model 3382 100 kn Metals Testing Packages For High Capacity Testing At An Affordable Price
Instron Offers A New Package With "Touchpanel" Controller For QC Testing
Instron Offers Its Dynatup 8100 Series For High Energy Impact Testing
Instron Offers Affordable 3300 Series Starter Packages For Tensile and Compression Testing
Instron Introduces New Metals Testing Brochure
Instron introduces a new controller for its 3300 series electromechanical instruments
Instron Introduces Biopuls Multi-Station Spinal Disc Wear Debris Testing System - Tests up to six Intervertebral Disc devices simultaneously
Wilson Instruments Unveils New Web Site - Completely redesigned, new site is more user-friendly and informative
Instron Announces Its New Exclusive Web Support Agreement - 24/7 access to your laboratory’s support requirements
Instron introduces Bluehill 2 software, bringing intuitive operation and unmatched functionality to materials testing applications.
Instron announces the grand opening of its state-of-the-art worldwide headquarters in Norwood, Massachusetts
Features, control, interface, measuring, monitoring, data integrity, optional features, hardware options
万能材料試験システム5800シリーズは低荷重から高荷重まで幅広く対応いたします。高性能ロード・フレーム、高速応答、高精度を特徴とするアドバンスドDSP技術を備え、即時性、高い操作性、恒常性を提供いたします。 <カタログNO: WB1132J> 2003年12月版
Bringing a dynamic dimension to force measurement
The new Instron® 8870 series of servohydraulic testing systems are ideal for fatigue and static testing of biomedical, advanced materials and manufactured components. These tabletop systems are compact and flexible enough to be located anywhere in your laboratory, saving valuable space. The 8871 system even uses a single phase, air cooled power pack so that no additional services are required.
Instron®’s new 8801 hydraulic testing system is designed to give the maximum return on investment, through improved productivity in a value engineered package.
Block loading software for use with FastTrack 8800 servohydraulic testing systems.
さまざまな動的アプリケーションに対応する高精度疲労試験システム。特に極限の環境条件下での耐久性の測定が必要な航空業界、自動車およびその部品業界などに幅広く使用されています。 <カタログNo.:WB1103BJ> 2003年5月版
This is a Model 3300-based package for Tire testing, primarily intended for the Chinese market.
da/dN software for use with FastTrack 8800 servohydraulic testing systems
LabView Drivers for use with FastTrack 8800 servohydraulic testing systems
WaveMakerソフトウェアはクリープ疲労、シーケンス負荷、製品耐久性、高・低サイクル疲労といった広範な疲労試験に対応します。頻繁な試験条件の変更を必要とする場合にも、簡単な操作で試験を再設計することが可能です。 <カタログNo.:WB1097BJ> 2003年12月版
MAXソフトウェアは、高・低サイクル疲労、ブロック負荷、ランダム負荷、単軸および多軸といったあらゆる疲労試験用として設計されています。品質管理上必要とされる耐久試験や製品の寿命試験としてもご利用いただけます。 <カタログNo.:WB1096BJ> 2003年12月版
Catalog number 2714-002 Rated capacity 50 N (5 kgf, 11 lbf) Suitable for a wide range of linear densities (denier and tex)
このカタログでは、金属業界が直面する多くの試験課題を概説すると共に、 Instron の試験装置ソリューションを使用して見事に解決している事を説明
Simulates hip joint loading and motion.
The BioPuls Dual Station ASTM Hip sy stem applies physiologically accurate loads and a range of motions including flexion-extension, abduction-adduction and inward rotation on a test specimen, while it is soaked in a serum bath maintained at +37 °C. The unique Dual-Station philosophy incorporates an upper test specimen and a lower control station.
Catalog describing miscellaneous Dynatup impact accessories.
Brochure describing Instron's complete Pendulum product line.
Instron Calibration Lab Expands Scope of NVLAP ISO 17015 Accreditation
CBS' Hit Drama, CSI Miami, To Feature Instron Testing Machine on January 5, 2004
White paper discussing fundamental theories of board level drop impact testing and a study of the fracture characteristics of solder interconnections under high-speed impact using Instron's new Micro Impact tester.
MicroImpact tester for the electronics industry.
Testing solutions for wire, rope and cable. WB1160B
FastTrack2, K1C, Fracture toughness software - WB1102B
FastTrack2 - J1C Unloading compliance software.- WB1102B
5800 Series incorporates is a high performance materials testing system controller combining ultra-high data and control loop update rates with flexible and accessible test functionality... - WB1143B
J1c Software for use with FastTrack 8800 servohydraulic testing systems wb 1107b
Fatigue - FastTrack 2 - Random Spectral Playback. Instron's 32 bit Random software enables you to generate complex waveforms with recorded and derived data, to simulate in-service loading conditions.- WB1102B
LCF software for use with FastTrack 8800 servohydraulic testing systems. WB1102B
K1c Software for use with FastTrack 8800 servohydraulic testing systems wb1100b
Full scale capacity ±5 kN to ±200 kN (500 kgf, 1,124 lbf to 20,000 kgf, 44, 960 lbf) Catalog number 2525-108/112 2518-100/101/102/103/107/111
Catalog number 2732-003
A review of developments in testing technology in the context of fracture test methodologies proposed and underdevelopment for measurement of interfacial properties.
Rated capacities from ±2.5 N to ± 100 kN (0.25 kgf to 10,000 kgf, 0.5 lbf to 22,500 lbf) ISO DIS 7500/1, EN10002-2, BS1610 (1992) and JIS B7721, B7733
Universal materials testing software for static hydraulic, electromechanical and torsion testing systems - WB1154B
The MicroRockwell series 2001M hardness tester is a hybrid instrument that combines typical microhardness test loads and a high precision depth measurement system to perform high speed, direct reading microhardness tests.
EXTEND the system life and capability of your 1340 testing system by upgrading the control system to meet today's demanding testing requirements.
This white paper summarizes topics discussed during a three day conference, held at Instron in November 2003 between software developers and a consultant expert, on the physics of metals testing and recent improvements to the calculation algorithms used in Instron Merlin software. Items of interest include test control, changeover criteria, determination of the end of the discontinuous yielding region, and the effect of speed changes on both data and calculations.
Replacement tissues for the human body's natural tissues are being developed at a rapid pace in an increasingly competitive market. - pod_SalineTesting_REV2_0504
Technical information for 8800 tower controller
TSOP is an accessory for the 8800 and 5800 series test frames to allow for combined test control and method control on an easy to use touch screen. - pod_2410-901_rev1_0304
The Instron® Dynatup® line of piezoelectric tups are ideally suited for use in impact testing of thin films and other ultra-low load materials. Designed to be used with Dynatup's ImpulseTM data acquisition systems, the piezoelectric line compliments the existing line of semiconductor strain gauge tups.
Instron®'s Dynatup Mini-Tower impact testing system is a compact, table top system designed for low energy impact simulation testing. Designed with a small footprint, the Mini-Tower can achieve energies of up to 18 J (13.2 ft-lb) and velocities up to 3 m/s (9.8 ft/sec). The Mini-Tower system performs impact simulation, penetration, and rebound testing. The system is available with the Dynatup ImpulseTM data acquisition system with a wide range of tups and fixtures. The Mini-Tower is also available without instrumentation for simple pass/ fail test evaluations.
Catalog Number 2525-171/ 172 Full scale capacity ±150 kN (15,000 kgf, 33,750 lbf) ±200 kN (20,000 kgf, 45,000 lbf) ISO DIS 7500/1, EN10002-2, BS1610 (1992) and JIS B7721, B7733
Wilson Instruments conversion wallchart is a valuable tool when comparing different hardness scales, although values can only be considered approximations.
A detailed knowledge of the mechanical properties is required in order to ensure good process yields and reliable products.
Hydraulic tension tester with capacity of 1000 kN (220,000 lbf) - pod_TVL_REV3_0104
Technical specifications for 8800 desktop controller.- pod_88desktop_REV1_1103
Detailed description including specifications of Wilson Instruments twin scale digital hardness tester for regular and superficial scale testing with one tester, Model 524T. POD_524MR/T_series_0804
Catalog number 2716-010
Catalog Numbers 2630-050/ 051/ 052
Instron Corporation manufactures a wide range of products used for materials testing. The major product lines are: - Servohydraulic tension and compression testers - Electromechanical tension and compression testers - Impact testers - Hardness testers
Instron ’s Dynatup model EC8250 environmental conditioning system is compatible with 9210, 9250, 8210, and 8250 Dynatup instrumented impact test systems. Its simple design, large storage capacity, ease-of-access, and precise temperature control help facilitate fast and efficient environmental testing.
Rated capacity 30 kN (3,000 kgf, 6,700 lbf) Temperature range: -73 °C to 250 °C (-100 °F to 480 °F) Catalog number 2716-015
Catalog number: 2714-010 Rated capacity 5 kN (500 kgf, 1,125 lbf) Suitable for testing a wide range of tire cords, braided wire and mono-filements
Catalog number 2714-107 Rated capacity 10 kN (1,000 kgf, 2,250 lbf) Suitable for testing a wide range of tire cords, braided wire and mono-filements.
Catalog No: 2712-003. Pneumatic action grips for rapid, easy loading of specimens from delicate films to polymers and woven fabrics. - pod_2712_003b_1002
Full scale capacity ±300 kN (30,000 kgf, 67,500 lbf) ±600 kN (60,000 kgf, 135,000 lbf) Catalog Number 2525-114/ 123
Rated capacities from ±10 N to ±5 kN (1 kgf to 500 kgf, 1 lbf to 1,125 lbf)
Catalog number 2525-108/112 Full-scale static rated capacities from ±5 kN to ±200 kN (500 kgf, 1,124 lbf to 20,000 kgf, 44, 960 lbf). Full-scale dynamic rated capacities from ±2.5 kN to ±100 kN (250 kgf, 562 lbf to 10,000 kgf, 2,248 lbf).
Designed for rigid plastics per ASTM D 695, reinforced plastics per ASTM D 3846 and then included high-modulus composites as well. Conforms to: SACMA SRM 1-88 Catalog Number 2505-021/ 022
Applicable to ASTM C 297 for sandwich constructions. Suitable for use from -150 °C to 315 °C (-240 °F to 600 °F) Catalog Number 2505-013/ 014/ 015
An ideal system for educating students about the mechanical properties of materials and small assemblies. It is a compact, versatile, configurable test instrument capable of tension, compression, bending, shear, flex, in a vertical mode. - Catalog no. 8840-700 - pod_LabMaster_001a_0109
Testing and Analysis - TestingForHyperelastic, July, 2000
Catalog numbers W-5180 and W-5190. Rated capacity of 300 kN and 600 kN. Round specimens up to 60 mm (2.36 in) in diameter and flat specimens up to 70 mm (2.75 in) thick.
The SF868 split furnace is highly versatile and has a proven track record of outstanding reliability. The case is constructed from polished stainless steel with aluminum and hardened insulation end plates. Heated via a wire wound heating element and insulated with high grade ceramic fiber insulation.
Floor-standing, dual ballscrew design with load capacities of 50 kN (11,000 lbf) or 100 kN (22,000 lbf).
Motorized testers with a dual column design for spring testing up to 25 kN (5,625 lbf).
Hydraulic compression testers with capacities up to 5,000 kN (1,100,000 lbf). pod_RD_REV5_0304
Designed for testing at high temperatures while still using standard grips and fixtures.
This chamber system consists of an insulated environmental enclosure (custom designed), an indirectly coupled heating and cooling plant (air handler) and a humidity plant, connected by insulated hoses. The air handler combines all heating and cooling systems, together with the control system and connected services.
Instron's new FastTrack 8860 electromechanical testing systems integrate all the mechanical system components into a standard package design.
In close co-operation with IST of Darmstadt, Germany, German automobile manufacturer Adam Opel AG have installed a ‘deterioration’ test system for complete vehicles, enabling extreme mechanical and environmental loads to be simulated in the laboratory within a minimum of time but with highest accuracy.
Biaxial HydropulsTM test rigs for automotive wheels and hubs - POD: IST0032 AE
SATEC™’s origins trace back to the early 1900’s and encompass a number of famous testing equipment companies including Southwark™, Baldwin™, Wiedemann™, Sonntag™, and Arcweld™.
Article from: Elastomer Seal Performance, January 2002.
A dual purpose flyer outlining the structural testing solutions and fatigue testing solutions with Instron machines
The chamber is heated up to 350 °C (662°F) with optional cooling to -70 °C (-94 °F) using LN2 or CO2. Includes safety interlocks and wedged ports allowing complete access to the load string.
2820-009 Compression Fixture - Parallel to Grain Meets BS 373 and ASTM D 143 Designed for 50 mm x 50 mm x 200 mm (2 in x 2 in x 8 in) specimens
Meets ASTM D 143 2820-007 Tension Grips- Parallel to Grain 30 kN (3000 kgf, 6750 lbf) force capacity Designed for 25 mm (1 in) x 460 mm (18 in) long specimens
2820-006 Adhesive Bond in Tension Fixture Meets ASTM D897 10 kN(1000 kgf, 2250 lbf) force capacity Designed for 48 mm (1.875 in) diameter shaped specimens
2820-005 Nail or Screw Withdrawal Fixture 25 kN (2500 kgf, 5625 lbf) force capacity for screw withdrawal 10 kN (1000 kgf, 2250 lbf) force capacity for nail withdrawal Designed for 50 mm x 50 mm x 150 mm (2 in x 2 in x 6 in) specimen sizes Meets ASTM D 143, ASTM D 1037 and ASTM D 1761
The micro bend fixture is designed for 3-point flexure testing of miniature components and specimens, where the specimen is supported on two lower anvils and load is applied by a single upper anvil at the center of the specimen.
The micro bend fixture is designed for 3-point flexure testing of miniature components and specimens. The fixture has a fixed 1 mm (0.04 in) span.
The tension grips are designed to perform static tensile tests on shoulder-ended and threaded-end test specimens to various international standards.
Catalog number 2715-010 Tests a variety of wire cables
Upgrade Systems Extend MTS Fatigue Hydraulic Frames
Upgrade Systems Extend Schenck Fatigue Hydraulic Frames
Upgrade Systems Extend 8500 Classic Series Fatigue Hydraulic Frames
Technical specifications for Dynatup 9250 Specimen Feeder System. Includes standard and optional features plus machine capabilities.
Stainless steel tubing (or any other variety of rigid metallic tubing) can be difficult to test in tension for two reasons. Standard methods of gripping will cause the tubing to collapse and lead to pre-mature failure of the specimen. Strain measurement is also usually not possible with traditional clip-on extensometers because the knife-edges lead to high stress concentrations and consequently failure of the thin specimen wall. The purpose of this testing was to recommend a gripping solution and evaluate the use of the Advanced Video Extensometer (AVE) for accurate, non-contacting strain measurement.
Catalog number 2717-068
Catalog Number 2717-056 Rated capacity 250 kN (25,000 kgf, 56,200 lbf) Temperature range: 0 °C to 150 °C (32 °F to 302 °F)
Catalog number 2716-203
Catalog Number 2716-110/ 2716-120 Rated capacity 100 kN (10,000 kgf, 22,500 lbf) and 200 kN (20,000 kgf, 45,000 lbf) Round specimens up to a 50 mm (2 in) diameter flat specimens up to a 40 mm (1.57 in) thickness.
Catalog number 2716-017
Catalog number 2716-016
Catalog number 2716-015
Catalog number 2716-003
Catalog number 2716-002
Meets requirements of ISO 9513, ASTM E83 and EN10,002 part 4
Wide operating temperature range, from -80 °C to 200 °C (-112 °F to 392 °F) Designed to meet the requirements of ISO 9513, BS 3846 and ASTM E 83
Operational and installation Manual for 2810-400 Flexure fixture
ISTがシミュレーションとコンポーネント試験用として開発した最新のデジタルコントローラです。Windowsに完全対応したPCベースの独自のソフトウェアにより世界で最も先進的な試験制御システムとなっています。 <カタログNo.:IST0001DEJ> 2004年9月版
Tom Davies, Product Manager for Servohydraulic Machine Products at the Instron Materials Testing Division, gives a presentation on the trends within dynamic materials testing.
Microindentation/ Vickers Hardness Tester. The instrument for determining Vickers and Knoop hardness.
Comprehensive 8-page brochure describing the Rockwell 2000 Closed-Loop hardness tester. The Series 2000 uses a unique closed-loop electronic control system and load cell mounted directly on the indenter to eliminate errors. This ensures that preliminary and total forces are applied with unparalleled accuracy and repeatability.
The Solution for Your Testing Requirements.
The IST Multi-Axis Shake Table (MAST) systems are designed for vibration testing of a wide range of test specimens. Vibration input can be generated in up to six-degrees of freedom (6-DOF), either individually or simultaneously. IST0021CE
油圧サーボ試験システムに最適な油圧パワー・ユニットです。<カタログNo. pod_HPU_Rev2_0604J> 2004年8月版
RS Consoleは、Labtronic 8800コントローラをコンピュータで制御するためのフロントパネルを提供します。 <カタログNo.:IST0010BEJ> 2004年9月版
【RS LabSite modulogicの旧バージョンです。】RS LabSiteは、最高の試験性能を提供するソフトウェアモジュール群です。物理的試験と仮想プロトタイプの組み合わせにより、究極の統合デジタル試験環境を提供します。 <カタログNo.:IST0060BEJ> 2004年9月版
Catalog number 2715-003/ 004 Rated capacity 50 kN (5000 kgf, 11250 lbf)
Pneumatic tire cord grips provide a convenient method for clamping tire cord and braided wire to reduce the problem associated with testing these materials. A guide pin allows for easy loading onto a graduated radius cam. This cam provides a stress reduced clamping area on the specimen.
Catalog Number 2714-032 Rated capacity 2 kN (200 kgf, 450 lbf) Suitable for a wide range of linear densities (denier and tex)
Catalog number 2713-004 Rated capacity 2 kN (200 kgf, 450 lbf) Temperature range: -70 °C to 315 °C (-94 °F to 600 °F) Ideal for testing elastomers, flexible plastics and thin films.
Catalog number 2713-003 Rated capacity 2 kN (200 kgf, 450 lbf) Ideal for testing elastomers, flexible plastics and thin films. Temperature range: -70 °C to 315 °C (-94 °F to 600 °F)
Catalog number 2713-002 Rated capacity 5 kN (500 kgf, 1,125 lbf) Ideal for testing elastomers, flexible plastics and thin films. Temperature range: -70 °C to 315 °C
Pneumatic action grips allows rapid, easy loading of specimens from delicate films to polymers and woven fabrics. This provides a very simple and efficient method for holding test specimens easily and quickly.
Catalog number 2712-016 Rated capacity 2 kN (200 kgf, 450 lbf)
Catalog number 2712-015 Rated capacity 1 kN (100 kgf, 225 lbf)
Catalog number 2712-014 Rated capacity 250 kN (25 kgf, 50 lbf)
Catalog number 2712-013 Rated capacity 5 N (0.500 kgf, 1 lbf)
Catalog number 2712-004 Rated capacity 1 kN (100 kgf, 225 lbf) Specimens from delicate films to polymers and woven fabrics.
Catalog number 2712-003 Rated capacity 1 kN (100 kgf, 225 lbf) Specimens from delicate films to polymers and woven fabrics.
Catalog number 2712-001 Rated capacity 5 N (0.5 kgf, 1 lbf) Specimens from delicate films to polymers and woven fabrics.
Catalog Number 2711-001/ 006 Rated capacity 5 N (0.5 kgf, 1.1 lbf) For single fiber specimens and very fine wire.
Catalog Number 2710-004 Rated capacity 500 N (50 kgf, 112 lbf) wide range of specimen thickness
Catalog Number 2640-010
New techniques based on Fracture Mechanics principles for properties in mode I, II and mixed mode fracture offer the ability to determine the fundamental materials and interfacial properties needed to properly model package designs.
Cyclic tests were run on conveyor belt material in accordance with ISO 9856.
A Gage Repeatability & Reproducibility (GR+R) study to determine how much of the process tolerance is being used up by variation in the testing instrument (equipment variation or repeatability) as well as between operators (appraiser variation or reproducibility).
Overview of Analog Microhardness Wilson-Wolpert Series 401 and 402 testers for Knoop and Vickers testing. Includes specifications, capabilities, standard accessories and recommended options.
The Labtronic® 8400 Controller is a digital servohydraulic controller, designed specifically for component testing.
One page overview of Wilson Instruments floor model Brinell hardness testers. Model AP specially suited for high-volume, production testing; Model K is a heavy-duty hydraulic tester. Direct-reading option available. POD _Model K-10, AP, KDR-10, AP-DR _0804
One page overview of Wilson Instruments Brinell benchtop models MJ and J. Model MJ is a motorized Brinell tester; Model J is a manually-operated system. POD _Model MJ/J _0904
Comprehensive 40+ page catalog of Accessories for Wilson Instruments hardness testers. Includes anvils, specimen support fixtures, test blocks and indenters for Rockwell, Brinell, Knoop/Vickers, and portable testers.
Temperature calibration services for environmental chambers, furnaces, process controllers, recorders and readouts.
Spring testing software for use with SF series load frames. - pod_PartnerSpring_REV2_0304
RS Accelerating the Durability Testing Process A key challenge in durability testing is the ability to accurately reproduce test track loading histories on the test rig. RS TWR (Time Waveform Replication) software was developed by two partners from The Durability Alliance (Instron® Structural Testing Systems (IST) and LMS), with the specific objective of achieving this goal in the shortest possible time and with maximum accuracy.
These specially developed tube furnaces feature resistance wire elements capable of achieving temperatures up to +1000 °C (+1832 °F). The furnace comprises of a resistance wire wound worktube, low mass insulation surrounded by a high quality stainless steel case which prevents the insulation cracking in service.
These specially developed three zone tubular creep furnaces feature resistance wire elements capable of achieving actual specimen temperatures of +1200 °C (+1832 °F). The furnace comprizes of a resistance wire wound worktube, low mass insulation surrounded by a polished stainless steel case.
This unique chamber is designed to enclose a variety of bend fixtures with a split line and removable door in the plane of the testing machine columns.
The chamber is heated via a mineral insulated element located next to a fan at the rear of the chamber. The forced air is channeled using a baffle plate to the top and bottom of the chamber and returned through the center of the baffle plate.
This robust furnace is designed for use with a range of test frames and is ideal for numerous high temperature applications.
Designed for testing at high temperatures while still using standard grips and fixtures.
The chamber is heated via a mineral insulated element located next to a two speed fan at the rear of the chamber. The convected air is channelled using a baffle plate to the top and bottom of the chamber and returned through the center of the baffle plate.
The chamber is heated via a mineral insulated element located next to a two speed fan at the rear of the chamber. The convected air is channelled using a baffle plate to the top and bottom of the chamber and returned through the center of the baffle plate.
The chamber is heated via a mineral insulated element located next to a two speed fan at the rear of the chamber. The convected air is channelled using a baffle plate to the top and bottom of the chamber and returned through the center of the baffle plate.
The furnace uses an extruded heating tile for easy service and is typically used for materials testing applications where sample temperatures up to +1050 °C (+1922 °F) are achievable (depending on loadstring configuration). The standard configuration has a high quality stainless steel case which provides rigid mounting for extensometers.
Solutions for testing at high freqencies (up to 1000Hz) often used with many elastomeric components.
The drip tray provides a means of keeping the test area clean when evaluating the texture of wet, juicy semi-solid or easily fractured foods. The stainless steel and ABS plastic parts are easy-to-clean and provide excellent corrosion resistance. Three drip tray designs are available. One for the model 1000/ 1011, one for the model 4411 and one that fits all remaining models. Some texture fixtures mount directly into the drip tray. Others use the catalog number 2830-014 support frame or an adapter plate. Tapped holes and a precision locator ring in the base plate provides flexibility for mounting special fixtures. All drip tray versions include a food fixture load cell adapter. Drip tray - Catalog Number 2830-033
General Biomedical flyer showing biomedical application solutions for hip, knee, and bi-axial testing systems
Rated capacities from ±5 N to ± 50 kN (0.5 kgf to 5,000 kgf, 1 lbf to 11,250 lbf) ISO DIS 7500/1, EN10002-2, BS1610 (1992) and JIS B7721, B7733 pod_2530-400_rev3_0704
Crack opening displacement pod_2670_rev3_0704
Model number 3119-402 (short version) Model number 3119-403 (tall version)
Encompassing a broad range of static and dynamic high capacity test applications from basic metals through rock mechanics to large scale structural testing.- pod_highcap_REV1_1103
The TMF system simulates the combined effects of mechanical fatigue and thermal cycling experienced by gas turbine and similar equipment. - pod_tmf_REV1_1103
The ARTEL (Advanced Rig for Testing Exhaust Lines) is a unique way of simulating both thermal and mechanical fatigue of complete exhaust systems. - POD: IST0033 AE
Platform to Launch Applications and Manage Test Results. RS BasLab modules provide the environment from which all RS LabSite® tests are performed. - IST0061BE
Multi-Axis Cyclic Testing with Monitoring and Analysis - IST0063BE
A module of the RS LabSite software suite which does single and multi-axis service load durability. Tests can be prepared locally, administered centrally and carried out on an appropriate test rig. - ST0064BG
The Viewer, a standard element of the RS BasLab package, is a comprehensive data viewer with basic editing features. RS SigEdit extends the capabilities of the Viewer with advanced editing and signal processing functions. - IST0065BE
FastTrack 8800 systems, combined with Instron frames, load cells, actuators and hydraulic power packs, provide machine control and data acquisition for a wide range of dynamic and static tests. Technical specifications on the common elements used for testing, and expected performance.- pod_8800 techspec_REV1_1103
FastTrack 8800 systems, combined with Instron frames, load cells, actuators and hydraulic power packs, provide machine control and data acquisition for a wide range of dynamic and static tests.
NATA certifies Instron Singapore Pte Ltd Calibration Laboratory complies with ISO 17025