+600 °C and +1000 °C Tension Only Pullrods (3117-020, 3117-021)
+600 °C and +1000 °C Tension Only Pullrods
Catalog numbers 3117-020, 3117-021
製品 11/07/2005 132.49 KB

2860 Series Stud Pull Fixture | 2860-300
The stud pull technique requires accurate specimen preparation and good test alignment. The stud pull test fixture incorporates swivels in both upper and lower sections and is self-aligning which ensures excellent test alignment. The specimen preparation fixture is a precision jig, which ensures the correct positioning of test specimen on the studs and maintains a constant load during the curing of the adhesive.
製品 11/07/2005 237.96 KB

2860 Series PCB Clamping Stage | 2860-200
The clamping stage can be mounted directly to the base of a testing machine or paired with an X‑Y translation stage such as the Instron® 2860‑101, allowing precise adjustment and indexing of the specimen’s position throughout testing. Download this data sheet to learn how the clamping stage supports accurate alignment and secure specimen positioning for reliable test results.
製品 11/07/2005 375.77 KB

2860 Series X-Y and Theta-X-Y Manual Translation Stage | 2860-100, 2860-101
The Theta‑X‑Y manual translation stage provides precise multi‑axis positioning to accurately align a test specimen beneath the actuator. Its digital micrometers allow fine adjustment of the theta (angle) and X‑Y axes, with a rotary axis readable to 5 minutes and X‑Y resolution down to 1 micron. With the angle stage at the base and the X‑Y stage on top, the platform can be oriented so the specimen is perfectly referenced to the test axes. Download this data sheet to learn how the stage enhances alignment accuracy for microelectronic and PCB testing.
製品 11/07/2005 279.77 KB

2712 Series Micro Pneumatic Grips (2712-202)
Pneumatic action grips allows rapid, easy loading of
specimens from delicate films to polymers and woven
fabrics. This provides a very simple and efficient
method for holding test specimens easily and quickly.
製品 11/07/2005 109.13 KB

2712 Series Micro Pneumatic Grips | 2712 -101
The grips clamp the specimen through lever arms actuated by air cylinders built into the grip body. The design include advantages of controllable and repeatable gripping force with normal air supplies, optimized clamping action for the material being tested, and reduction of specimen failure at the grip face. In addition, foot switch actuation means the operator’s hands are free for accurate specimen placement in the grip. The micro pneumatic grip is fatigue rated to a capacity of ±10 N. It is made of light weight material and is suitable for both monotonic and low cyclic testing with minimal inertia effect. In addition, with one fixed face and one movable face, the grips provide a large access area for repeatable and accurate specimen alignment, making them suitable for testing of micro test specimens like fine wires, thin films or single filaments.
製品 11/07/2005 208.89 KB

Rotating German Wheel Peel Fixture | 2820-026
The fixture consists of a 152 mm (6.0 in) diameter, 25.4 mm (1 in) wide, bearing mounted wheel. As the crosshead is driven in the tensile direction, the load weighing system measures the force of the tape or release coating pulling against the wheel. The rotation of the wheel maintains a constant 90° peel angle.
製品 11/07/2005 528.48 KB

3117-031 – +1000 °C (+1832 °F) Reverse Stress Pullrods
High-temperature reverse stress pullrods (Catalog 3117-031) designed for fatigue and tensile testing up to 1000 °C (1832 °F). Featuring backlash-free clamping, mechanical operation, and compatibility with Instron fixtures, these nickel-based superalloy pullrods ensure reliable performance through zero load cycles in demanding test environments.
製品 11/03/2005 171.61 KB

2810 Series Flexure Fixture
Catalog number 2810-200
Rated capacity 250 kN (25000 kgf, 56250 lbf)
3-point flexure fixture with an optional conversion kit for 4-point loading
製品 10/19/2005 287.25 KB